HEATING LOAD FORM
FRIEDRICH ROOM UNIT HEAT PUMPS
BTU/HR PER
WALLS: (Linear Feet °F. TEMP. DIFFERENCE
2" Insulation Lin. Ft. x 1.6
Average Lin. Ft. x 2.6
WINDOWS & DOORS (Area, sq. ft.
Single Glass: Sq. Ft. x 1.13
Double Glass: Sq. Ft. x 0.61
INFILTRATION - WINDOWS & DOORS: AVG. Lin. Ft. x 1.0
Loose L in. Ft . x 2.0
CEILING: (Area, Sq. Ft.)
Insulated (6") Sq. Ft. x 0.07
Insulated (2") Sq. Ft. x 0.10
Built-up Roof (2" insulated Sq. Ft. x 0.10
Built-up Roof (1/2" insulated) Sq. Ft. x 0.20
No Insulation Sq. Ft. x 0.33
FLOOR: (Area, Sq. Ft.)
Above Vented Crawl space
Insulated (1:) Sq. Ft. x 0.20
Un-insulated Sq. Ft. x 0.50
* Slab on Ground Lin. Ft. x 1.70
1" Perimeter insulation Lin. Ft. x 1.00
* Based on Linear Feet of outside wall TOTAL HEAT LOSS PER °F BTU/HR/°F
Multiply total BTU/HR/°F X 30 and plot on the graph below at 40°F. Draw a straight line from the
70 base point thru the point plotted at 40°F. The intersection of this heat loss line with the unit
capacity line represents the winter design heating load.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Friedrich 2000 TwinTemp YS09J10-1 and is the answer not in the manual?

Friedrich 2000 TwinTemp YS09J10-1 Specifications

General IconGeneral
BrandFriedrich
Model2000 TwinTemp YS09J10-1
CategoryAir Conditioner
LanguageEnglish

Related product manuals