EasyManua.ls Logo

Friedrich EMWRT-1 - Appendix 1: Energy Saving Presets

Friedrich EMWRT-1
26 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
24
APPENDIX 1 - Energy Saving Presets
SCREEN
NUMBER
Level
0
Level
1
Level
2
Level
3
Level
4
Level
5
19 Temperature Control Mode AUTO AUTO AUTO AUTO AUTO AUTO
01 Fan Control Mode AUTO AUTO AUTO AUTO AUTO AUTO
17 Minimum Setpoint 64°F 64°F 65°F 66°F 67°F 68°F
18 Maximum Setpoint 82°F 82°F 80°F 78°F 76°F 74°F
20 Deadband 2 2 2 2 2 2
02 1st Stage Differential - Heat 0.5°F 0.5°F 0.5°F 0.5°F 0.5°F 0.5°F
03 2nd Stage Differential - Heat 1°F 1°F 1°F 2°F 2°F 2°F
04 1st Stage Differential - Cool 0.5°F 0.5°F 0.5°F 0.5°F 0.5°F 0.5°F
07 Forced 2nd Stage Heating 30’ 30’ 30’ 30’ 30’ 30’
10 Recovery Time 0’ 15’ 20’ 25’ 30’ 0’
16 Recovery Temperature - Cool 71°F 72°F 73°F 74°F 75°F 76°F
11 Recovery Temperature - Heat 70°F 69°F 68°F 67°F 66°F 65°F
15 Maximum Setback Temperature 72°F 74°F 76°F 78°F 80°F 82°F
13 Minimum Setback Temperature 67°F 66°F 65°F 64°F 63°F 62°F
12 Setback Delay - Heat 0’ 30’ 25’ 20’ 15’ 10’
14 Setback Delay - Cool 0’ 30’ 25’ 20’ 15’ 10’
05 Guest Occupancy Threshold 0’ 5’ 5’ 5’ 5’ 5’
06 Night Occupancy Threshold 0’ 1’ 1’ 1’ 1’ 1’
08 Night Occupancy Start 18 19 20 21 22 23
09 Night Occupancy End 12 11 10 9 8 7
19 Auto Restore Off On On On On On
20 Setback Setpoints Off On On On On On
21 Temperature Calibration 0.0 0.0 0.0 0.0 0.0 0.0