TROUBLESHOOTING
Outdoor Fault Codes
Fault code Fault description Possible reasons for
abnormality
How to deal with Remarks
17 Discharge temperature
sensor fault
"1.The wiring of the discharge
temperature sensor is
connected loosely;
2.The discharge temperature
sensor fails;
3.The sampling circuit is
abnormal."
"1. Reconnect the wiring of
the discharge temperature
sensor;
2. Replace the discharge
temperature sensor fails;
3. The sampling circuit is
abnormal."
18 AC voltage is abnormal 1.The AC voltage>275V or
<160V.
2.The AC voltage of sampling
circuit on the driver board is
abnormal.
"1. Normal protection,
please check the supply
power;
2. Replace the driver board."
19 Suction temperature
sensor fault
"1.The wiring of the suction
tempe‑ rature sensor is
connected loosely;
2.The suction temperature
sensor fails;
3.The sampling circuit is
abnormal."
"1. Reconnect the wiring
of the suction temperature
sensor;
2. Replace the suction
temperature sensor;
3. Replace the outdoor
control board."
22 The defrosting sensor fault "1. The wiring of the defrosting
sensor
is connected loosely;
2. The defrosting sensor fails;
3. The sampling circuit is
abnormal."
"1. Reconnect the wiring of
the defrosting sensor;
2. Replace the defrosting
sensor;
3. Replace the outdoor
control board."
23 Expansion valve A tube
(thin) sensor fault
"1. The wiring of the sensor
for the expansion valve A(thin
tube) connect loose;
2. The sensor for the
expansion A(thin tube) is
failure;
3. The sampling circuit is
abnormally"
"1. Reconnect the wiring of
the sensor for the expansion
valve A (thin tube);
2. Replace the sensor for
the expansion valve A (thin
tube);
3. Replace the outdoor
control board."
24 Expansion valve B (thin)
tube sensor fault
"1. The wiring of the sensor
for the expansion valve B (thin
tube) connect loose;
2.The sensor for the expansion
valve B(thin tube) is failure;
3.The sampling circuit is
abnormally"
"1. Reconnect the wiring of
the sensor for the expansion
valve B(thin tube);
2.Replace the sensor for
the expansion valve B(thin
tube);
3. Replace the outdoor
control board."
25 Expansion valve C (liquid)
pipe sensor fault
"1. The wiring of the sensor for
the expansion valve C (liquid
pipe) is connected loosely;
2. The sensor of the expansion
valve C (liquid pipe) fails;
3. The sampling circuit fails."
"1. Reconnect the wiring of
the sensor for the expansion
valve C (liquid pipe).
2. Replace the sensor for the
expansion valve C (liquid
pipe);
3. Replace the outdoor
control board."
26 Expansion valve D (liquid)
pipe sensor fault
"1.The wiring of the sensor for
the expansion valve D (liquid
pipe) is connected loosely;
2.The sensor of the expansion
valve D (liquid pipe) fails;
3.The sampling circuit fails."
"1. Reconnect the wiring of
the sensor for the expansion
valve D (liquid pipe);
2. Replace the sensor for the
expansion valve D (liquid
pipe);
3. Replace the outdoor
control board."