Refrigeration Gauges rated for A2L Refrigerants with temp scales for R-32 refrigerant.
Gauge Manifold (Right handed threads).
A2L compatible Vacuum Gauge capable of 300 microns or less.
Nitrogen regulator for purging and testing, rated to 800 psi. (Capable of low psi flow)
Pipe tubing cutter.
Refrigerant recovery cylinder. (Flammable A2L label)
Ventilation fan.
Class ABC fire extinguisher.
Process Tube adapter kit
Recovery access tool.
Purge hose fittings
Pinch off and opening tools
R-32 SEALED SYSTEM REPAIR
Required Equipment
27
Process tube adapter kit
Pinch off and opening tools
Recovery access tool
Purge hose fittings
Recovery Machine
Vaccum Pump
Nitrogen
ABC Fire Extinguisher
Guage Manifold
Nitrogen Regulator
Vaccum Guage