EasyManua.ls Logo

Frigidaire FFLE4033QW - E5 H: Motor Control under Voltage; E5 C: Motor Control over Voltage

Frigidaire FFLE4033QW
195 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
183
E5H
E5H: Motor control under voltage
E5H
Low input AC voltage, Wiring or motor control board, Main board.
Checks to perform:
E5C
E5H: Motor control under voltage
E5C
Low input AC voltage, Wiring or motor control board, Main board.
Checks to perform:
WARNING
Check that all the connectors are correctly inserted.
WARNING
Check that all the connectors are correctly inserted.
Is the power supply as per product specification? (Voltage =
240V (Electric), 120V (Gas) Models and Frequency = 60HZ)
Make the power supply proper as per product
specification and repeat the Diagnostic Cycle to check
for any further alarms.
Is the wiring between Main Control Board and Motor
Control Board proper? (Check for the continutity)
Replace / Repair the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Replace the Main Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Replace the Main Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
Is the wiring between Main Control Board and Motor
Control Board proper? (Check for the continutity)
Replace / Repair the wiring and repeat the Diagnostic
Cycle to check for any further alarms.
Replace the Motor Control Board and check for further
alarms. Is the appliance ok?
Replace the Main Control Board and repeat the
Diagnostic Cycle to check for any further alarms.
Y
E
S
Y
E
S
NO
NO
NO
NO
NO
NO
Y
E
S
Y
E
S

Table of Contents