Do you have a question about the Frigidaire FPGF3077QF and is the answer not in the manual?
Brand | Frigidaire |
---|---|
Model | FPGF3077QF |
Product Type | Range |
Fuel Type | Gas |
Color | Stainless Steel |
Cooktop Surface | Gas |
Number of Burners | 5 |
Burner Type | Sealed |
Oven Capacity | 5.0 cu. ft. |
Oven Type | Single |
Convection | Yes |
Self-Cleaning | Yes |
Width | 30 inches |
Warranty | 1 Year |
Ensure the anti-tip device is properly installed and re-engaged when moving the range.
What to do if you smell gas: do not light, do not use phones, call gas supplier or fire department.
Range preset for natural gas; LP conversion, installer/consumer notes, and MA requirements.
Do not operate electric ignition during power failure; reset controls to OFF.
Never leave children unattended; teach proper use of appliances.
Avoid stepping/leaning on doors/drawers; do not store items above range.
List of tools needed for leveling legs, anti-tip bracket, and gas supply connection.
List of materials required, including sealant, shut-off valve, and flexible conduit.
Components provided with the appliance for installation.
Dimensions and clearances required when installing the range with cabinets.
Minimum distances to combustible walls based on burner BTU output.
Critical warning about tipping risk and the importance of the anti-tip bracket.
Step-by-step instructions for locating, drilling, and fastening the anti-tip bracket.
Details on natural gas and LP pressure, inlet pressure limits, and altitude adjustments.
Installing manual shut-off valve and flare union adapter to the pressure regulator.
Instructions for sealing openings in walls and floors after gas supply installation.
Proper torque and stabilization methods for gas fittings and appliance conduit.
Procedure for checking gas leaks using a liquid leak detector at all joints.
Guidance on connecting a manometer to check manifold gas pressure for Natural Gas and LP.
Disconnect power before servicing; never cut grounding prong.
Dedicated 15A circuit, proper grounding, and polarized receptacle requirements.
Strict precautions if an extension cord is necessary, must be UL listed and rated.
Importance of proper grounding and checking the wall receptacle.
Ensure burner caps and grates are correctly installed on matching burner heads.
How to check if burner caps are centered and firmly seated by gently sliding them.
Steps to check surface burner ignition, including purging air and verifying flame within seconds.
Detailed steps to adjust the low flame setting of burner valves for stable operation.
Steps to check oven and broil burner ignition, including timing and flame verification.
How to adjust the air shutter for the upper oven burner to achieve proper flame color and size.
Refer to user manual for detailed cleaning instructions; shut off utilities when servicing.
Guidance on common issues that can be resolved without a service technician.
Information on where to find the appliance's identification plate.
How to level the range using leveling legs or shims for stability.