FRIGOMAT GX4Kompact, GX6, GX8 M04.42026 R.2019.05.30 17
P Description Min Max. Step Default Note
P1 Model selection 1 2 1 2 1= GX2-GX4, 2= GX8-GX6-GX4K
P2 Probe alignment CYLINDER -10° +10° 0,1° -
P3 Probe alignment SUCTION -10° +10° 0,1° -
P4 Forzed freezing 0” 250” 1” 25”
P5 Probe temperature CYLINDER pr.1 +10° -30° 0,1° -3,0°
P6 Probe temperature SUCTION pr.1 -10° -50° 0,1° -18,5°
P7 Probe temperature CYLINDER pr.2 +10° -30° 0,1° - 4,0°
P8 Probe temperature SUCTION pr.2 -10° -50° 0,1° -18,5°
P9 Probe temperature CYLINDER pr.3 +10° -30° 0,1° -11,5°
P10 Probe temperature SUCTION pr.3 -10° -50° 0,1° -29,5°
P11 Probe temperature CYLINDER pr.4 +10° -30° 0,1° -12,0°
P12 Probe temperature SUCTION pr.4 -10° -50° 0,1° -29,5°
P13 Probe temperature CYLINDER pr.5 +10° -30° 0,1° -12,5°
P14 Probe temperature SUCTION pr.5 -10° -50° 0,1° -30°
P15 Probe temperature CYLINDER pr.6 +10° -30° 0,1° -13°
P16 Probe temperature SUCTION pr.6 -10° -50° 0,1° -30°
P17 Probe temperature CYLINDER pr.7 +10° -30° 0,1° -14°
P18 Probe temperature SUCTION pr.7 -10° -50° 0,1° -33°
P19 Forzed pause time after freezing 0’ 15’ 1’ 5’
P20 Time ON cyclic agitation 0” 120” 1” 0”
P21 ΔT CYLINDER probe for restart compressor in preservation +0° +20° 0,1° 7°
P22 Growth failure alarm (Time-out) 0 2 1 2 0= Off, 1= 1 h, 2= 2 h
P23 Temperature orobe safety limit SUCTION -10° -50° 0,2° -44°
P24 Priority (if P1=2) 0 1 1 1
0 : give priority. 1 : does not give
priority
P25 Extra agitation time 0” 120” 1” 0”
P26 CYLINDER probe temperature to restart the compressor in night mode +10° -30° 0,1° +4,5°
P27 SUCTION temperature probe to stop the compressor in night mode -10° -50° 0,1° -15°
P28 Filter display 0 10° 1° 0
P29 Display °C/°F 0 1 1 1 1 = °C, 0 = °F
P30 Restart time freezing limit OFF 60’ 1’ 35’
P31 ΔT probe safety CYLINDER to stop compressor in preservation 0 10° 0,1°
2° - W
1° - A
P32 Delay starting compressor 0 10” 1” 0”
P33
Mixing after Cn storage
0 20’ 1’ 0’
TAB V/01 : Programming chart