iT /C /L O R "» y
2.
Condensation pressure (water models
only).
With the machine in production mode, after a
few seconds condensation water must come
out of the drain pipe at a temperature of about
35®C. If this is not the case, the pressure switch
valve shown in the figure must be adjusted.
A c a u t i □ n/ \
Three-phase machines are powered with three-
phase + neutral lines: be careful never to
connect the phase lines with neutral. TAYLOR
will not be held liable for damage to the
machine deriving from incompliance with this
rule.
Press the STOP button to stop the machine .
Operating temperature should be between 15“ and 35“C.
Humidity should be between 30 and 60%.
/ \ d a n g e r A
TAYLOR will not be held liable for personal harm and/or damage to objects deriving from
incorrect installation and/or by failure to comply with work accident-prevention standards.
Never intervene on the machine with your hands, neither during normal operating cycles
nor during cleaning and maintenance, without first having stopped the machine by
pressing the STOP button and having turned off the master switch. Never clean the
appliance using a high-pressure water jet. Never shut the water cut-off cock while the
machine is running. Be careful never to damage the power cable. If so, have it replaced.
Machines with water cooling which are left in places at a temperature below or close to
0“C, must first have all the water drained from the condenser.
11 - ENGLISH