2.5 Installing the new combustion chamber
NOTICE! Before installing the combustion chamber, note the colour markings. Only
stones with a red marking may be installed!
Position the pallet provided in front of the boiler
Place the bottom of the new combustion chamber on the pallet and boiler base
Place the top of the new combustion chamber on top of the bottom
Insert the secondary air bushing into the top of the combustion chamber from the
outside
The flat part must be facing down
Unscrew the clamping screws until the thread of the screws no longer protrudes
into the bushing
2
Replacing the combustion chamber
Installing the new combustion chamber
8 Froling GesmbH | A-4710 Grieskirchen, Industriestraße 12 | www.froeling.com