4.3 Emissions measurement by chimney sweep or regulatory body
Various legal regulations stipulate that heating systems must be inspected
periodically. In Germany this is regulated by the First Federal Emissions Protection
Ordinance (BimSchV) in the last amended version, and in Austria by various state
laws.
The following minimum requirements must be met by the operator of the system for a
successful measurement:
Thoroughly clean the boiler immediately before the measurement
Only use fuels of high quality which meet the requirements as stipulated in the
boiler operating instructions (“Permitted fuels” chapter)
Ensure that there is adequate heat consumption on the day of the measurement.
(e.g. storage tank must be able to take heat for the duration of the measurement)
4.3.1 Preparing for the measurement
There must be a suitable measuring port in the straight flue gas pipe for the
measurement. The measuring port must be twice the flue gas pipe diameter away
from the last upstream bend.
If the measuring port is not correctly positioned, the measuring result will be
distorted
Ensure that there is enough combustion air
Prepare adequate fuel
Ensure that there is adequate heat dissipation
Clean the boiler thoroughly for the emissions measurement
4.3.2 Emissions measurement by chimney sweep or regulatory body
Immediately before the start of the measurement:
Activate “Chimney-sweep mode” in the quick menu
The flue gas temperature and residual oxygen content should have stabilised
approximately 20 minutes after activation
The display will indicate that the boiler is ready for measurement
4.4 Maintenance agreement / Customer service
NOTICE! We recommend a yearly inspection by Froling customer services or an
authorised partner (third party maintenance).
Regular maintenance and servicing by a heating specialist will ensure a long, trouble-
free service life for your heating system. It will ensure that your system stays
environmentally-friendly and operates efficiently and cost-effectively.
Boiler Servicing
4
Emissions measurement by chimney sweep or regulatory body
Operating Instructions T4 24-150 | B0830317_en 39

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Froling T4 Series and is the answer not in the manual?

Froling T4 Series Specifications

General IconGeneral
BrandFroling
ModelT4 Series
CategoryBoiler
LanguageEnglish

Related product manuals