EasyManua.ls Logo

Fromm FS360 Series - Alarms E3 and E4; Safety Contact (Base) and No Pallet Detect Troubleshooting

Fromm FS360 Series
51 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
SERVICE MANUAL FS360_EN01 Version00.doc
FROMM
For further updates, see our website www.fromm-stretch.com and Login!
It is forbidden to duplicate this manual or parts thereof or any other form without the author’s authorisation © 2018
41
ALARMS
E3: Safety contact 3x beep / warning light (repeated sequence)
The safety device on the base d.1650mm (yellow carter)
Problem suggestion
Possible solution
- This alarm signal has been activated by the limit
switch of the base
- Check the situation, an object or person
has been positioned between mast and
turntable. (Fig. 1)
- Re-move this object or person.
- Limit switch not working properly (or not
connected)
- Replace the limit switch (2) (Fig. 2).
- The spring is positioned incorrectly
- Position the spring (3) correctly (Fig. 3).
- The plate have been blocked mechanically
- Release the plate.
Fig. 1
Fig. 2
Fig. 3
The doors are open
Problems detected
Possible solutions
- The door is open
- Check whether the door has been
closed properly.
- Door closure sensors do not work properly
- Check the cables;
E4: No pallet detect 4x beep / warning light (repeated sequence)
There is no pallet on the turntable;
Problems detected
Possible solutions
- The pallet has not been detected by the photocell
- Dark goods? Dark film? Replace the
photocell with laser photocell
- Photocell is not properly connected
- Check that the cables/connections
arrive at the board.
- Photocell malfunction
- Replace the photocell
2