NOTE!
Danger from charging dry batteries (primary cells).
This can result in damage to property.
It is not permitted to use this charger to charge dry batteries (primary cells).
Connecting/
disconnecting
the battery
WARNING!
Danger due to connecting or disconnecting the battery while the charger is con-
nected to the grid.
This can result in serious injury and damage to property due to short circuits and arcs.
Before connecting/disconnecting the battery, disconnect the charger from the grid.
During operation, check that charging terminals and battery poles are properly con-
nected.
Establish a connection as follows:
1
Unplug the device from the grid
2
Plug charging lead into charger connection socket
3
Connect (+) charging terminal to positive pole (red) on battery
4
Connect (-) charging terminal to negative pole (black) on the battery, or to vehicle
body (e.g. engine block) in the case of vehicle power supplies.
WARNING!
Danger due to incorrect battery disconnection sequence.
This can result in serious injury and damage to property due to short circuits and arcs.
When disconnecting, it is imperative to follow the above instructions in the reverse
order to avoid short circuits and arcs.
If using an on-board or system plug to connect the charging lead, steps 3 and 4 do not
apply. Instead, connect charging lead to a suitable on-board socket.