Power curve at underfrequency with hysteresis.
General - Frequency-dependent Power Control
Parameter Range of val-
ues
Description Availability
"Return Gradi-
ent 1"
0.01 100 [%/s
]
Rate of change at which
the inverter increases the
effective power after the
limitation has ended.
"Return Gradi-
ent 1 Alternat-
ive"
0.01 100 [%/s
]
Rate of change at which
the inverter increases the
effective power after the
limitation has ended. This
is activated if the differ-
ence between the rated
power and the current re-
duced power is greater
than the "Return Gradient
1 Alternative Threshold".