132
The device data unit of the new 
RECERBO must also be broken off 
and returned to Fronius with the faulty 
RECERBO.
Connect the broken off device data unit 
(4) to the inside of the new RECERBO
Fit the RECERBO holder (3) to the new 
RECERBO
- feed it in from above
- press downwards
Insert the new RECERBO module
The RECERBO holder locking devices 
(2) must be fully engaged in the 
housing shell
Insert the external fan cable into the 
cable guide (1)
Insert the Datamanager card, close the 
inverter and place it in the wall bracket 
(see "Replacing the Datamanager 
card" and "Opening and closing the de-
vice" sections)
(4) (3)
NOTE! If you forget to connect the 
device data unit or do not connect 
it correctly, the inverter will show 
status code 482 on the display.
NOTE! All guide bolts and pins 
must be properly engaged.
1
2
3
(1)
(2) (2)
4
5
6
7