42,0410,2148 011-28052019
Fronius Primo
3.0-1 / 3.5-1 / 3.6-1 / 4.0-1
4.6-1 / 5.0-1 AUS / 5.0-1
5.0-1 SC / 6.0-1 / 8.2-1
Operating Instructions
Grid-connected inverter
Instructions de service
Onduleur pour installations photo-
voltaïques connectées au réseau
Gebruiksaanwijzing
Inverter voor netstroomgekoppelde
fotovoltaïsche installaties
ENFRNL
www.youtube.com/FroniusSolar
LEARN MORE WITH
OUR HOW-TO VIDEOS

Table of Contents

Other manuals for Fronius Primo 4.0-1

Questions and Answers

  • L
    Leslie WestSep 23, 2025
    How to handle purge openings for cooling air on Fronius Inverter?
    • J
      Jonathan WhiteSep 23, 2025
      Purge openings for cooling air and the heat sink if necessary.
  • J
    Jennifer PetersenAug 23, 2025
    How to troubleshoot total display failure on Fronius Inverter?
    • L
      Leah MorrisAug 23, 2025
      If the display on your Fronius Inverter has failed completely, check the AC voltage on the inverter connections. It should be 230 V (+10% / -5%).
  • J
    Jessica WeissAug 25, 2025
    What to do if Fronius Inverter shows Overcurrent (AC) error?
    • B
      Benjamin BeckerAug 25, 2025
      The fault should rectify automatically. However, if the Fronius Inverter continuously displays this status code, you should notify a Fronius trained service engineer.
  • R
    Robin WardAug 27, 2025
    Why is my Fronius Primo 4.0-1 Inverter showing LOW PV OUTPUT?
    • B
      Brandon ArnoldAug 27, 2025
      A 'LOW PV OUTPUT' status code on your Fronius Inverter can be due to the low level of insolation. However, if this code appears when there is sufficient insolation, contact your system engineer.
  • W
    Wendy BaileyAug 27, 2025
    What causes LOW PV VOLTAGE on Fronius Inverter?
    • S
      Susan CareyAug 27, 2025
      The 'LOW PV VOLTAGE' status code on your Fronius Inverter may appear due to the low level of insolation. If this status code occurs when there is sufficient insolation, contact your system engineer.
  • W
    wfreySep 18, 2025
    What happens when DC input voltage MPPT 2 is too high on Fronius Primo 4.0-1?
    • S
      Spencer HensonSep 18, 2025
      When the DC input voltage MPPT 2 is too high, the Fronius Inverter resumes with its start-up routine.
  • L
    Lauren DavidsonSep 15, 2025
    What happens when DC input voltage is too low for feeding energy into the grid on Fronius Primo 4.0-1 Inverter?
    • M
      Mr. Thomas MillerSep 15, 2025
      When the DC input voltage is too low for feeding energy into the grid, the Fronius Inverter resumes with its start-up routine.
  • F
    franklin71Sep 16, 2025
    What happens when DC input voltage MPPT 1 is too high on Fronius Primo 4.0-1?
    • A
      Alyssa CarlsonSep 17, 2025
      When the DC input voltage MPPT 1 is too high, the Fronius Inverter resumes with its start-up routine.
  • K
    Kara GreenSep 6, 2025
    What happens when AC frequency is too high on Fronius Primo 4.0-1 Inverter?
    • L
      Lisa GarciaSep 6, 2025
      If the AC frequency is too high, the Fronius Inverter will resume feeding energy into the grid.
  • R
    Randy RossSep 3, 2025
    What happens when AC voltage is too high on Fronius Primo 4.0-1?
    • M
      Mr. Jason BrownSep 4, 2025
      If the AC voltage is too high, the Fronius Inverter will resume feeding energy into the grid.

Fronius Primo 4.0-1 Specifications

General IconGeneral
Purpose-
Output power4000 W
Input voltage80 - 1000 V
Output voltage180 - 270 V
Input frequency- Hz
Output frequency50/60 Hz
Power supply typeUniversal
Power current typeDC-to-AC
Output power capacity4 kVA
Quantity per pack1 pc(s)
Product colorBlack, Grey

Related product manuals