Page #14 background imageLoading...
Page #14 background image
14
System monitoring
General The inverter is fitted with the WLAN-enabled system monitoring Fronius Datamanager 2.0
as standard.
The following functions are included with the system monitoring:
- Dedicated web page displaying current data and a wide range of settings
- Ability to connect to Fronius Solar.web using WLAN or LAN
- Automatic sending of service messages by SMS or e-mail in the event of a fault
- Option of controlling the inverter by specifying power limit values, minimum or maxi-
mum running times or target running times
- Control of the inverter via Modbus (TCP / RTU)
- Ability to assign control priorities
- Ability to control the inverter by means of connected meters (Fronius Smart Meter)
- Ability to control the inverter via a ripple control signal receiver (e.g. by specifying the
reactive power or effective power)
- Dynamic power reduction, taking self-consumption into account
Further information on Fronius Datamanager 2.0 can be found online in the Fronius Data-
manager 2.0 Operating Instructions.
Fronius Dataman-
ager during the
night or when the
available DC volt-
age is insufficient
The Night Mode parameter under "Display Settings" in the Setup menu is preset to OFF in
the factory.
For this reason the Fronius Datamanager cannot be accessed during the night or when the
available DC voltage is insufficient.
To nevertheless activate the Fronius Datamanager, switch the inverter off and on again at
the mains and press any function button on the inverter display within 90 seconds.
See also the chapters on "Menu items in the Setup menu", "Display settings" (Night Mode).
Using for the first
time
Setting up the Fronius Datamanager 2.0 for the first time is made considerably easier with
the Fronius Solar.web app. The Fronius Solar.web app is available in the respective app
stores.
When starting Fronius Datamanager 2.0 for the first time,
- the Fronius Datamanager 2.0 plug-in card must be installed in the inverter,
or
- there must be a Fronius Datamanager Box 2.0 in the Fronius Solar Net ring.
IMPORTANT! In order to establish a connection to Fronius Datamanager 2.0, "Obtain IP
address automatically (DCHP)" must be activated on the end device in question (e.g. lap-
top, tablet, etc.).

Table of Contents

Other manuals for Fronius Primo 4.0-1

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Primo 4.0-1 and is the answer not in the manual?

Fronius Primo 4.0-1 Specifications

General IconGeneral
Purpose-
Output power4000 W
Input voltage80 - 1000 V
Output voltage180 - 270 V
Input frequency- Hz
Output frequency50/60 Hz
Power supply typeUniversal
Power current typeDC-to-AC
Output power capacity4 kVA
Quantity per pack1 pc(s)
Product colorBlack, Grey

Related product manuals