Technical data
FRONIUS PRIMO 3.0-1 3.5-1 3.6-1
Input data
MPP voltage range 200 - 800 V
Max. input voltage
at 1,000 W/m²/ 14 °C in an open circuit
1000 V
Max. input current (MPPT 1 / MPPT 2) 12.0 A
Max. short circuit current of the solar modules 18.0 A
Max. feedback current
4)
18.0 A
Output data
Nominal output power (P
nom
) 3000 W 3500 W 3680 W
Max. output power 3000 W 3500 W 3680 W
Nominal grid voltage 1 ~ NPE 220 / 230 / 240 V
Min. grid voltage 150 V
1)
Max. grid voltage 270 V
1)
Max. output current 13.7 A 16.0 A 16.8 A
Nominal frequency 50 / 60 Hz
1)
Total harmonic distortion < 5 %
cos phi power factor 0.85 - 1 ind./cap.
2)
Max. permissible mains impedance Z
max
on PCC
3)
None
Power-up current pulse
6)
and duration
Max. output fault current per period 38 A / 172 ms
General data
Maximum efficiency 98.0 % 98.0 % 98.0 %
European efficiency 96.1 % 96.8 % 96.8 %
Overnight self-consumption 0.6 W
Cooling Controlled forced-air ventilation
Degree of protection IP 65
Dimensions h x w x d 628 x 428 x 205 mm
Weight 21.6 kg
Permissible ambient temperature -40 °C - +55°C
Permitted humidity 0 - 100%
EMC device class B
Overvoltage category DC / AC 2 / 3
Protection devices
DC insulation measurement Warning/shutdown
7)
at R
ISO
< 1 mOHM
Response to DC overload Operating point shift, power limitation
DC disconnector Integrated