124
Replacing the 8 
kW mains cable
Removing the mains cable:
Remove the AC connecting plate (see 
the "Opening the device" section)
Disconnect the mains cable (1) from 
the primary power module
Undo the PE connection (2) from the 
flat pin
Undo the three cable ties (6, 7, 8)
Unwind the mains leads from the ferrite 
cores (3, 4)
Use a slotted screwdriver to loosen the 
strain-relief device (5)
 Thread out the mains cable
Installing the mains cable:
Insert the new mains cable through the 
strain-relief device (5) and tighten with 
the slotted screwdriver
[2 Nm]
Wind the individual phase leads three 
times through the larger ferrite core (3) 
and the PE lead twice 
Secure with a cable tie (6) 
Also wind the PE lead twice through 
the smaller ferrite core (4) and secure 
with a cable tie (7) 
Connect the mains cable (1, 2) on the 
primary power module and the flat pin 
in the correct sequence
Make sure the mains leads are neatly 
laid and secure with a cable tie (8) 
Fit the AC connecting plate (see the 
"Closing the device" section)
(1)
(6) (2)(5) (7) (8)
(3) (4)
1
2
3
4
5
6
7
(1)
(6) (2)(5) (7) (8)
(3) (4)
1
2
3
4
5
6
7