Possible applications:
operating a heat pump or an air-conditioning system using as much self-generated power
as possible
Time / Date Set the time, date and automatic changeover between summer and winter time
Display settings
Setting range Set time / Set date / Time display format / Date display format /
Summer/winter time
Set time
Set the time (hh:mm:ss or hh:mm am/pm – depending on the setting for the time display
format)
Set date
Set the date (dd.mm.yyyy or mm/dd/yyyy - depending on the setting for the date display
format)
Time display format
For specifying the time display format
Setting range 12hrs / 24hrs
Factory setting Depends on country setup
Date display format
for specifying the date display format
Setting range mm/dd/yyyy / dd.mm.yy
Factory setting Depends on country setup
Summer/winter time
Activate/deactivate automatic changeover between summer and winter time
IMPORTANT! Only use the automatic summer/winter time changeover function if the
Fronius Solar Net ring does not include any LAN- or WLAN-compatible system compo-
nents (e.g. Fronius Datalogger Web, Fronius Datamanager or Fronius Hybridmanager).
Setting range on / off
Factory setting on
IMPORTANT! The time and date must be set accurately in order for the day and year val-
ues and for the day characteristic to be displayed correctly.
Setting range Language / Night mode / Contrast / Illumination
Language
Set language for display
Setting range German, English, French, Dutch, Italian, Spanish, Czech, Slo-
vak, etc.
Night mode
DATCOM night mode; controls DATCOM and display operation during the night or when
the DC voltage is insufficient

Table of Contents

Other manuals for Fronius Symo 10.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo 10.0-3-M and is the answer not in the manual?

Fronius Symo 10.0-3-M Specifications

General IconGeneral
Max. output current16.7 A
Max. input voltage1000 V
MPP voltage range200 - 800 V
Number of MPP trackers2
Protection classIP 65
AC voltage range150 - 280 V
Frequency50 / 60 Hz
THD< 3 %
AC Nominal Power10000 W
MPPT Voltage Range200 - 800 V
AC Frequency50 / 60 Hz
AC nominal output10000 W
Max. apparent AC power10000 VA
DC input voltage range200-1000 V
Operating Temperature-25°C to +60°C
Dimensions (W x H x D)725 x 510 x 225 mm
AC nominal voltage3 x 230 / 400 V