Disconnect both fan cables (1) from
the SymoFIL and remove the lower ca-
ble from the cable guide (2)
NOTE!
Turn the inverter carefully so that the
back of the inverter is accessible.
Undo the two 5x14 TX25 screws (3)
Loosen the locks (6) for the air duct on
both sides
Remove the seal plugs (4) on both si-
des
Carefully remove the air duct and en-
sure that the fan cables are pulled out
Push the fan holders (5) outwards on
both sides and remove the external fan
Inserting the External Fan:
NOTE!
Ensure the air is flowing into the device!
Snap the new external fan into the air
ducts
2
(3) (3) (4)
(6)
3
4
5
6
(5)
7
1

Table of Contents

Other manuals for Fronius Symo 6.0-3-M

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius Symo 6.0-3-M and is the answer not in the manual?

Fronius Symo 6.0-3-M Specifications

General IconGeneral
AC Nominal Output6.0 kW
Max. Input Voltage1000 V
MPP Voltage Range200 - 800 V
Number of MPP Trackers2
Protection RatingIP66
Efficiency98.1%
Max. Apparent AC Power6.0 kVA
Frequency50 / 60 Hz
THD< 3%
Protection ClassI
DC ConnectionMC4
Operating Temperature Range-25°C to +60°C
DC Input Voltage Range200-1000 V
AC ConnectionScrew terminals
CoolingForced air cooling

Related product manuals