Parameters for
TIG welding
Para-
meter Description Range Unit
 
Operating mode (trigger mode)    
-
Operation using welding torch without a
torch trigger
OFF  
-
2-step mode 2t  
-
4-step mode
Factory setting: 2t
4t  
Starting current (I-Start)
This parameter is only available in 4-step
mode (tri = 4t)
Factory setting: 35%
1 - 200 Percent
Reduced current
This parameter is only available in 4-step
mode (tri = 4t)
Factory setting: 50%
1 - 200 Percent
Final current (I-End)
This parameter is only available in 4-step
mode (tri = 4t)
Factory setting: 30%
1 - 100 Percent
Gas pre-flow time (Gas Pre flow)
Duration of gas pre-flow
Factory setting: 0.0 seconds
0.0 - 9.9 Second
s
Gas post-flow (Gas Post flow)
Specified period during which gas flows at the
end of welding
Factory setting: AUt
AUt
0.2 - 25
Second
s
Gas purging (gas purging)
Purging of the protective gas shield begins as
soon as GPU is allocated a value. For safety
reasons, purging of the protective gas shield
cannot be restarted until a new GPU value is
entered.
IMPORTANT! Purging the shielding gas is ne-
cessary if condensation forms when the
device is left unused in a cold environment for
a prolonged period. Long hosepacks are most
affected.
Factory setting: off
0.1 - 9.9 Minutes