Do you have a question about the Fronius AccuPocket 150 and is the answer not in the manual?
Welding current range (SMAW) | 10-150 A |
---|---|
Welding current range (GTAW) | 3-150 A |
Protection class | IP23 |
Mains Voltage | 230 V |
Mains Frequency | 50/60 Hz |
Insulation Class | H |
Power supply voltage | 230 V |
Power supply frequency | 50/60 Hz |
Efficiency | 85% |
Power factor | 0.99 |
Specifies products covered by the service instructions and highlights safety precautions.
Covers electrostatic discharge measures and provides contact information for technical support.
Details required servicing equipment and provides a functional overview of the device.
Guides fault diagnosis and refers to detailed component descriptions for problem resolution.
Provides flowchart overview and troubleshooting for 'No lights on control panel' errors.
Lists service codes, their causes, and corresponding remedies for device faults.
Outlines standard points for component descriptions: designation, overview, function, connections, LEDs, and measuring points.
Provides a detailed description of the ACCUPLT PC board, including its function, connections, and LED indicators.
Covers safety, ESD, and the initial steps for opening/closing the device housing.
Provides instructions for removing and installing the AccuPack battery.
Details procedures for replacing the ACCUPLT PC board and the cooling fan.
Outlines inspection procedure, responsibility, and visual checks according to IEC 60974-4.
Covers insulation resistance and open circuit voltage testing for device safety compliance.
Details tests for indicators, controls, gas solenoid valve, and VRD function.
Specifies requirements for documenting test results and marking passed/failed devices.