Replacing the AccuPack
Removing the
AccuPack
1
Open housing as described in the
"Opening the housing" section
2
Remove the TX25 screw (1) of the
negative lead of the AccuPack
3
Insulate the negative lead with the
insulating sleeve from the new Ac-
cuPack and secure the sleeve with
a cable tie
4
Remove the cable tie (a)
5
Disconnect plug (2)
6
Disconnect the gas hose from the
AccuPack
7
Remove six TX20 screws (3)
8
Remove two TX25 screws (4) and
remove the device feet
9
Fold the back cover (5) away to the
side
10
Remove the AccuPack
33