Fronius AccuPocket 150 - LED Checklist; Measuring Points

Fronius AccuPocket 150
48 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Pin 1 +15 V Pin 2 Fan GND
X 11 Solenoid valve
Pin 1 +15 V Pin 3 NC
Pin 2 GND valve Pin 4 NC
X 12 16 pin Molex - battery control
LED checklist
LED Function
-15V green Lights up when the -15 V supply voltage is present
15V - S5 green Lights up when the +15 V supply voltage is present
S5 red Gate signal - lights up when the power module is activated
S3 red Gate signal - lights up when the power module is activated
15V - S3 green Lights up when the +15 V supply voltage is present
15V green Lights up when the +15 V supply voltage is present
5V green Lights up when the +5 V supply voltage is present
3V3 green Lights up when the +3.3 V supply voltage is present
TX CAN green Flashes when data is sent to the battery
RX CAN green Flashes when data is received by the battery
V40 green Lights up permanently
V52 green Has no function – permanently unlit
Error red Flashes if an error occurs.
S1 Gate signal - lights up when the power module is activated
15V - S1 Lights up when the +15 V supply voltage is present
TX Flashes when data is sent to the control panel
RX Flashes when data is received by the control panel
Measuring points There are no measuring points on the ACCUPLT PC board.
25