Service codes for push-pull calibration
Safety
Service codes
when the drive
units are disen-
gaged ("open-cir-
cuit" calibration)
Err | Eto
Cause: Incorrect measurement during push-pull calibration
Remedy: Repeat push-pull calibration
St1 | E 1
Cause: At minimum wire feed speed, the wire-feed unit motor does not deliver any ac-
tual rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St1 | E 2
Cause: At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St1 | E 3
Cause: At minimum wire feed speed, the wire-feed unit motor does not deliver any ac-
tual rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St1 | E 4
Cause: At minimum wire feed speed, the wire-feed unit motor does not deliver any ac-
tual rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St1 | E 5
Cause: At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
St1 | E 6
Cause: At maximum wire feed speed, the wire-feed motor does not deliver any actual
rotational speed value.
Remedy: Repeat the push-pull calibration. If the error message re-appears: Contact Af-
ter-Sales Service.
WARNING! An electric shock can be fatal. Before opening the device
- Turn the mains switch to the "O" position
- Unplug the machine from the mains
- Prevent it from being switched on again
- Using a suitable measuring instrument, check to make sure that electrically
charged components (e.g. capacitors) have discharged

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals