EMF measures
Specific hazards
Check for possible problems, and check and evaluate neighbouring devices'
resistance to interference according to national and international require-
ments:
- Safety features
- power, signal and data transfer lines
- IT and telecommunications devices
- measuring and calibrating devices
Supporting measures for avoidance of EMC problems:
a) Mains supply
- if electromagnetic interference arises despite correct mains connec-
tion, additional measures are necessary (e.g. use a suitable line fil-
ter).
b) Welding leads
- must be kept as short as possible
- must run close together (to avoid EMF problems)
- must be kept well apart from other leads
c) Equipotential bonding
d) Earthing the workpiece
- if necessary, establish an earth connection using suitable capacitors.
e) Shielding, if necessary
- shield off other nearby devices
- shield off entire welding installation
Electromagnetic fields may pose as yet unknown risks to health:
- effects on the health of others in the vicinity, e.g. wearers of pacemakers
and hearing aids
- wearers of pacemakers must seek advice from their doctor before ap-
proaching the device or any welding that is in progress
- for safety reasons, keep distances between the welding cables and the
welder's head/torso as large as possible
- do not carry welding cables and hosepacks over the shoulders or wind
them around any part of the body
Keep hands, hair, clothing and tools away from moving parts. For example:
-Fans
- Cogs
- Rollers
-Shafts
- Wirespools and welding wires
Do not reach into the rotating cogs of the wire drive or into rotating drive com-
ponents.
Covers and side panels may only be opened/removed while maintenance or
repair work is being carried out.
During operation
- ensure that all covers are closed and all side panels are fitted properly.
- keep all covers and side panels closed.

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals