St2 | E 14
Cause: At maximum wire feed speed, the motor current of the wire-feed unit motor is
outside the permitted range. Possible reasons are disengaged wire-feed unit
motors or wire feed problems.
Remedy: Engage the drive units of both wire-feed unit motors, arrange the hosepack in
as straight a line as possible; check the inner liner for kinks or soiling; check
the contact pressure on the 2-roller or 4-roller drive of the push-pull unit. Re-
peat the push-pull calibration. If the error message re-appears: Contact After-
Sales Service
St2 | E 15
Cause: At maximum wire feed speed, the motor current of the push-pull unit is outside
the permitted range. Possible reasons are disengaged wire-feed unit motors
or wire feed problems.
Remedy: Engage the drive units of both wire-feed unit motors, arrange the hosepack in
as straight a line as possible; check the inner liner for kinks or soiling; check
the contact pressure on the 2-roller or 4-roller drive of the push-pull unit. Re-
peat the push-pull calibration. If the error message re-appears: Contact After-
Sales Service.
St2 | E 16
Cause: Push-pull calibration was interrupted: Quick-stop was activated by pressing
the torch trigger.
Remedy: Repeat push-pull calibration

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals