171
EN
no | IGn
Cause: Ignition time-out function is active: No current started flowing before the
length of wire specified in the Setup menu had been fed. The safety cut-out
of the power source has been triggered.
Remedy: Shorten the wire stick-out; press the torch trigger repeatedly; clean the sur-
face of the workpiece; if necessary, increase the setting in “Setup menu: Level
2” for the length of wire that is fed before the safety cut-out is triggered.
no | H2O
Cause: Cooling unit flow watchdog has been triggered
Remedy: Check the cooling unit; top up with coolant or bleed the water flow if necessary
(see cooling unit operating instructions). Then acknowledge the error by
pressing the Store button
no | Prg
Cause: No preconfigured program has been selected
Remedy: Select a configured program
r | E30
Cause: r-calibration: There is no contact with the workpiece.
Remedy: Connect the grounding (earthing) cable; ensure a tight connection between
the contact pipe and the workpiece
r | E31
Cause: r-calibration: Procedure has been interrupted by repeated pressing of the
torch trigger.
Remedy: Ensure a tight connection between the contact tube and the workpiece
press the torch trigger once only
r | E32
Cause: r-calibration: Grounding (earthing) cable, current cable or hosepack defective
(value is below 0.5 mOhm or exceeds 30 mOhm)
Remedy: Check grounding (earthing) cable, current cable or hosepack and replace if
necessary
r | E33
Cause: r-calibration: Poor contact between the contact tube and the workpiece.
Remedy: Clean the point of contact, tighten the contact tube, check the grounding
(earthing) connection
r | E34
Cause: r-calibration: Poor contact between the contact tube and the workpiece.
Remedy: Clean the point of contact, tighten the contact tube, check the grounding
(earthing) connection
tJO | xxx
At the same time, “E66” is displayed on the JobMaster
Note: xxx is a temperature value
Cause: Overheating in JobMaster welding torch
Remedy: Allow the torch to cool, then acknowledge the error by pressing the Store but-
ton

Table of Contents

Other manuals for Fronius TransPuls Synergic 5000

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fronius TransPuls Synergic 5000 and is the answer not in the manual?

Fronius TransPuls Synergic 5000 Specifications

General IconGeneral
BrandFronius
ModelTransPuls Synergic 5000
CategoryAC Power Distribution
LanguageEnglish

Related product manuals