Parameters for
manual metal arc
welding in Setup
menu 2nd level
SEt Country-specific setting (Standard/USA) ... Hour/US
Unit:
Setting range: Std, US (Standard/USA)
Factory setting:
Standard version: Std (dimensions: cm / mm)
USA version: US (dimensions: in.)
r r (resistance) - welding circuit resistance (in mOhm)
See the section "Measuring the welding circuit resistance r" from page 112.
L L (inductivity) - welding circuit inductivity (in microhenrys)
See the section "Displaying the welding circuit inductivity L" from page 114.
Parameters for
TIG welding
(Setup menu 2nd
level)
SEt Country-specific setting (Standard/USA) ... Hour/US
Unit:
Setting range: Std, US (Standard/USA)
Factory setting:
Standard version: Std (dimensions: cm / mm)
USA version: US (dimensions: in.)
C-C Cooling unit control
(only with TransSteel 3500c MP and if cooling unit is connected)
Unit:
Setting range: Aut, On, OFF
Factory setting: Aut
Aut: the cooling unit cuts out after a 2-minute welding off-time.
IMPORTANT! If the coolant temperature and flow monitoring options have been
installed in the cooling unit, the cooling unit cuts out as soon as the return-flow
temperature drops below 50 °C, but at the earliest after a 2-minute welding off-
time.
On: The cooling unit is always switched on
OFF: The cooling unit is always switched off
IMPORTANT! If the FAC welding parameter is used, the C-C parameter is not
reset to the factory setting. If the MMA welding process is selected, the cooling
unit is always switched off, even if the switch is in the "On" position.
C-t Cooling time
(only with TransSteel 3500c MP and if cooling unit is connected)
Time from when flow monitoring is triggered until the "no | H2O" service code is
output. For example, if there are air bubbles in the cooling system, the cooling
unit will not cut out until the end of this preset time.
Unit: s
Setting range: 5 - 25
Factory setting: 10
IMPORTANT!Every time the power source is switched on, the cooling unit carries
out a test run for 180 seconds.
111
EN-US

Questions and Answers: