G: JIB: Jug in a Box, holds oil for auto-
matic top-off system. It’s not used to fill
the vats, just to maintain the oil level. Use
only fresh oil in top off system.
NOTE: The Frymaster LOV™ fryer requires a start-up, demonstration and training before
normal restaurant operations can begin.
1. Turn on power switches (D).
2. Fill vats to lower fill line.
3. Turn computers on using the button.
4. Computer displays “CHANGE FILTER PAD?
YES/NO”
5. Press 91 (YES) and computer displays “REMOVE
PAN”
6. Remove pan and computer displays “CHANGE FIL-
TER PAD”
7. Assemble filter pan, ensuring pan is out 30 seconds.
Re-install filter pan.
8. Position JIB (Jug in a Box) in the right cabinet, placing
pick-up tube in open jug (G).
9. Press and hold the JIB reset switch until light goes out.
(F).
10. Ensure A is showing on the display of the MIB. A P in-
dicates the filter pan is not properly placed. Reseat the
filter pan if necessary.
11. While cooking, respond YES to the Filter Now Prompt
in display (B) and illuminated blue light (A) by pressing
the 91 (YES) button.
12. Respond to the JIB light (E) by replacing the JIB (G)
and resetting (F) or refilling the JIB with RTI system.
LOV
Quick Start:
819-6452 2-10
F: JIB reset button: Press and
hold after replacing the JIB until
yellow light goes out..
D: Power switch: One in cabinet under
each computer (domestic electric only).
C: MIB: Displays status of
system.
B: M3000: Programmable
for automatic filtering.
Press 91(YES) button to
respond YES to filter
prompt.
A: Filter light:
Illuminates
when it’s time to
filter.
E: JIB light: Illuminates when oil
reservoir is low.

Other manuals for Frymaster LOV

Questions and Answers

  • M
    Michael RichardsonAug 1, 2025
    What to do if the add pump is not operating on a Frymaster LOV Fryer?
    • K
      Kathleen HardyAug 1, 2025
      If the Add pump on your Frymaster Fryer isn't working, start by checking the voltage at the MIB board from Pin 1 to Pin 2. It should be 24 VAC. If it's not, inspect the connections from the RTI 24VAC transformer and the transformer itself at the RTI. Also, check the voltage at the MIB board from Pin 2 to Pin 3; it should also be 24 VAC. If not, the MIB board might be faulty, or the wires to the pump relay could be shorted. Finally, verify that the voltage at the Add pump relay is 24 VAC. If it isn't, check the wiring from the MIB board. The relay is located on top of the RTI system.
  • M
    Michael WatersAug 5, 2025
    What to do if the waste valve is not opening on a Frymaster Fryer?
    • J
      John Holloway MDAug 5, 2025
      If the waste valve on your Frymaster Fryer isn't opening, check the voltage at the MIB board from Pin 1 to Pin 2. It should measure 24 VAC. If it doesn't, check the connections from the RTI 24VAC transformer and inspect the transformer at the RTI. Also, check the voltage at the MIB board from Pin 2 to Pin 4, which should also be 24 VAC. If it's not, the MIB board may be bad, or the wires to the waste valve may be shorted. Finally, verify the voltage at the waste valve itself; it should be 24 VAC. If not, check the wiring from the MIB board.
  • C
    Cory ForbesAug 9, 2025
    What to do if the JIB valve is not opening on a Frymaster LOV?
    • M
      morrisglennAug 9, 2025
      If the JIB valve on your Frymaster Fryer isn't opening, check the voltage at the MIB board from Pin 1 to Pin 2. It should be 24 VAC. If it's not, check the connections from the RTI 24VAC transformer and the transformer itself at the RTI. Also, check the voltage at the MIB board from Pin 6 to Pin 7, which should also be 24 VAC. If it's not, the MIB board may be bad, or the wires to the JIB valve may be shorted. Finally, verify the voltage at the JIB valve itself; it should be 24 VAC. If it isn't, check the wiring from the MIB board.
  • S
    Stanley TateAug 18, 2025
    Why does one vat top off but other vats fail to top off on Frymaster LOV Fryer?
    • C
      Christina VazquezAug 18, 2025
      If one vat tops off but other vats fail to top off in your Frymaster Fryer, it could be due to a failed solenoid. Check the power to the pump. If the pump is hot, the solenoid has probably failed. Another possible reason is a loose wire connection. Ensure all wiring harnesses are securely connected to the ATO board and solenoids.
  • C
    Christine HillAug 22, 2025
    What to do if incorrect vat tops off in Frymaster LOV?
    • D
      Daniel CollinsAug 23, 2025
      If the incorrect vat is topping off in your Frymaster Fryer, it may be due to incorrect wiring. Ensure wires are wired correctly. Alternatively, the flexlines might be connected to the wrong vat. In this case, switch the flexlines to the correct vat.
  • R
    Richard MartinezAug 27, 2025
    How to fix yellow JIB low light that won’t illuminate on Frymaster Fryer?
    • J
      Judith GreenAug 27, 2025
      If the yellow JIB low light won’t illuminate on your Frymaster Fryer, it could be due to several reasons: * The auto top off power switch may be off. Verify that the auto top off power switch is switched on. The switch is located behind the JIB on the left side of the auto top off control box. * Power in the component box may not be present. Ensure power is present in the component box. * The transformer may have failed. If power is present in the component box, check the transformer for correct voltage. * There may be a loose wire connection. Ensure the yellow LED is securely attached to plug J6 on the ATO board.
  • N
    Nicholas PerkinsNov 13, 2025
    What to do if Frymaster LOV frypots won’t top off?
    • L
      Leslie EllisNov 13, 2025
      If the Frymaster Fryer frypots aren’t topping off, there are several potential causes: * The auto top off power switch might be off. Make sure it's switched on; it's behind the JIB on the left side of the auto top off control box. * The probe temperature might be lower than the setpoint. Check that the fryer is heating to at least 300°F (149°C) and check the probe resistance. Replace the probe if it's faulty. * The oil viscosity could be too thick. Make sure the oil is thin enough to pump. * There may be ATO board power loss. Restore power to the board and cycle all computers off and on to readdress system. * The solenoid could be failing, check it to see if it's functioning properly. * The ATO pump might have failed or been overtightened. If the solenoid is working, loosen th...

Summary

LOV Fryer Quick Start Procedure

Filter Light

Illuminates when it's time to filter.

M3000 Programmable Filter

Programmable for automatic filtering. Press 1 (YES) to respond.

MIB System Status Display

Displays the status of the system.

Fryer Power Switch

One in cabinet under each computer.

JIB Light Indicator

Illuminates when oil reservoir is low.

JIB Reset Button

Press and hold after replacing JIB until yellow light goes out.

JIB Oil Container

Holds oil for automatic top-off system to maintain oil level.

M3000 Button Guide and Navigation

M3000 Button Functions

Defines ON/OFF, Product, Cook Cycle, Filter, Temp, and Info buttons.

Navigation Quick Reference

Guides for Filter Menus, Programming Levels, and Info Mode.

Troubleshooting Common Issues

Addresses JIB topping off, filter pad changes, and vat oil levels.

Frymaster LOV Specifications

General IconGeneral
BrandFrymaster
ModelLOV
CategoryFryer
LanguageEnglish

Related product manuals