&DXWLRQ
&DXWLRQVZKHQ,QVWDOOLQJ
3OHDVHDYRLGLQVWDOOLQJLQWKHIROORZLQJORFDWLRQV
Ɣ/RFDWLRQVLQZKLFKWKHDPELHQWWHPSHUDWXUHIDOOVRXWVLGHWKHUDQJHRI±WR&ZKHQHTXLSPHQW
LVLQXVH,IWKH SRZHU VXSSO\LV9$&WKHUHFRPPHQGHGPD[LPXPDPELHQWWHPSHUDWXUHLV
45°C.)
Ɣ/RFDWLRQVZLWKUDSLGWHPSHUDWXUHFKDQJHVOHDGLQJWRGHZFRQGHQVDWLRQ
Ɣ/RFDWLRQVZLWKFRUURVLYHJDVHVHVSHFLDOO\VXO¿GHJDVDPPRQLDHWFRUÀDPPDEOHJDVHV
Ɣ/RFDWLRQVZLWKYLEUDWLRQRUVKRFNGLUHFWO\9LEUDWLRQDQGVKRFNPD\FDXVHRXWSXWUHOD\PDOIXQFWLRQ
Ɣ/RFDWLRQVLQFRQWDFWZLWKZDWHURLOFKHPLFDOVVWHDPRUKRWZDWHU
,IWKHHTXLSPHQWJHWVZHWWKHUH LV DULVNRIHOHFWULF VKRFN RUILUHVRKDYH LW LQVSHFWHGE\)XML
distributor.)
Ɣ/RFDWLRQVZLWKKLJKFRQFHQWUDWLRQVRIDWPRVSKHULFGXVWVDOWRULURQSDUWLFOHV
Ɣ/RFDWLRQVZLWKODUJHLQGXFWLYHLQWHUIHUHQFHUHVXOWLQJLQVWDWLFHOHFWULFLW\PDJQHWLF¿HOGVRUQRLVH
Ɣ/RFDWLRQVLQGLUHFWVXQOLJKW
Ɣ/RFDWLRQVWKDWEXLOGXSKHDWIURPUDGLDQWKHDWVRXUFHVHWF
Recommended site conditions
Ɣ$SODFHZKHUHWKHDPELHQWKXPLGLW\GXULQJRSHUDLRQLVEHWZHHQWR5+
About EMC standard
Ɣ7KLVHTXLSPHQWLVDFODVV$IRULQGXVWULDOORFDWLRQVHTXLSPHQW'RQRWXVHWKLVHTXLSPHQWLQGRPHVWLF
establishment, such as residential areas, or it may cause radio interference. If you use this equipment in
domestic locations, take adequate measures on the outside of the equipment to reduce radio interference.
Ɣ8QGHUWKHUHTXLUHPHQWRI(0&VWDQGDUGWKHPD[LPXPOHQJWKRIH[WHUQDOFDEOHLQFOXGLQJDVHQVRUWREH
connected to this equipment is 30 m. Do not connect the sensor longer than 30 m.
&DXWLRQVZKHQ$WWDFKLQJWRWKH3DQHOV
Ɣ,QVHUWWKHFRQWUROOHUXQLWLQWRWKHSDQHOFXWRXWIURP WKHIURQWDQGWKHQSXW WKHPRXQWLQJEUDFNHW
IURPWKHUHDU7KHPRXQWLQJEUDFNHWVKRXOGEHSXVKHGLQXQWLOWKHFRQWUROOHULVVHFXUHO\¿[HGWRWKH
SDQHO,IWKHUHLVDVOLJKWJDSUHPDLQLQJJHQWO\WLJKWHQWKHWZRVFUHZVXQWLOWKHJDSGLVDSSHDUV
0DNHVXUHQRW WRRYHUWLJKWHQWKHVFUHZV DVGRLQJVRPD\UHVXOW LQWKHPRXQWLQJEUDFNHW
separating from the stopper.)
Ɣ7KHIURQWRIWKLVHTXLSPHQWLVZDWHUSURRILQFRPSOLDQFHZLWK1(0$;VWDQGDUGV,3HTXLYDOHQW
7RHIIHFWZDWHUSURRIWKHLQFOXGHGSDFNLQJLVVKDOOEHDWWDFKHG EHWZHHQ WKHFRQWUROOHUDQGWKH
SDQHODFFRUGLQJWRWKHJXLGHOLQHVEHORZ,QFRUUHFWDWWDFKPHQWPD\FDXVHWKHHTXLSPHQWWRORVHLWV
ZDWHUSURRIFDSDELOLWLHV
$VVKRZQLQ)LJLQVHUWWRWKHSDQHODIWHUDWWDFKLQJWKHSDFNLQJWRWKHHTXLSPHQWFDVH
$VVKRZQLQ)LJWLJKWHQWKH¿[WXUHVFUHZVVRWKDWQRJDSVFDQUHPDLQEHWZHHQWKHHTXLSPHQW
IDFHWKHSDFNLQJDQG WKH SDQHOV2QFH¿QLVKHGFRQ¿UP WKDW WKHUHDUHQRFKDQJHV LQ VKDSH
VXFKDVGLVSODFHGRULPSURSHUO\¿WWHGSDFNLQJHWFDVVKRZQLQ)LJ
Ɣ,IWKHSDQHOGRHVQRWKDYHHQRXJKVWUHQJWKJDSVPD\GHYHORSEHWZHHQWKHSDFNLQJDQGWKHSDQHO
WRORVHZDWHUSURR¿QJFDSDELOLWLHV
Fig. 1 Fig. 2 Fig. 3
Screw
Mounting
bracket
Unit Unit
Front Case Panel Panel
Packing
Packing
Case
Case
(Bad)
(Good)
Packing
Attachment on vertical surface
+RUL]RQWDODWWDFKPHQW
Caution
Ɣ ,QRUGHUWRDLGKHDWGLVVLSDWLRQGRQRWEORFNWKHVLGHVRIWKHHTXLSPHQW
Ɣ 'RQRWEORFNWKHDLUYHQWVRQWKHWRSDQGERWWRPRIWKHFDVH
&DXWLRQVIRU:LULQJ
Ɣ)RUWKHUPRFRXSOHLQSXWXVHWKHGHVLJQDWHGFRPSHQVDWLRQOHDGIRUUHVLVWDQFHEXOELQSXWXVHZLUHV
ZLWKVPDOOOHDGZLUHUHVLVWDQFHDQGZLWKRXWDQ\UHVLVWDQFHGLIIHUHQFHDPRQJWKHWKUHHZLUHV
Ɣ7RDYRLGQRLVHFRQGXFWRUHIIHFWVLQSXWVLJQDOZLUHVVKRXOGEHVHSDUDWHGIURPHOHFWULFSRZHUOLQHVRU
load lines.
Ɣ,QSXWVLJQDOZLUHDQGRXWSXWVLJQDOZLUHVKRXOGEHVHSDUDWHGHDFKRWKHU$QGERWKVKRXOGEHVKLHOG
ZLUH
Ɣ,IWKHUHLVDORWRIQRLVHIURPWKHSRZHUVRXUFHDGGLQJDQLQVXODWLRQWUDQVGXFHUDQGXVLQJDQRLVH
¿OWHULVUHFRPPHQGHG
$OZD\VDWWDFKDQRLVH¿OWHUWRDSDQHOWKDWLVJURXQGHGVHFXUHO\DQGNHHSWKHZLULQJEHWZHHQWKH
QRLVH¿OWHURXWSXWVLGHDQGWKHPHDVXULQJHTXLSPHQWSRZHUWHUPLQDOZLULQJWRDPLQLPXPOHQJWK
3OHDVHGRQRWDWWDFKIXVHVDQGVZLWFKHVHWFWRWKHQRLVH¿OWHURXWSXWZLULQJRWKHUZLVHWKH¿OWHU¶V
HIIHFWLYHQHVVZLOOEHGHFUHDVHG
Ɣ7ZLVWLQJWKHSRZHUZLUHVLVHIIHFWLYHZKHQFRQQHFWLQJWKHZLUHV7KHVKRUWHUWKHSLWFKRIWKHWZLVW
the more effective the connection is against noise.)
Ɣ2SHUDWLRQSUHSDUDWLRQWLPHLVUHTXLUHGIRUWKHFRQWDFWRXWSXWZKHQSRZHULVWXUQHGRQ,IXVLQJLWDV
DVLJQDOWRDQH[WHUQDOLQWHUORFNFLUFXLWSOHDVHFRXSOHLWZLWKDGHOD\HGUHOD\
Ɣ&RQFHUQLQJWKHRXWSXWUHOD\FRQQHFWLQJWKHPD[LPXPUDWHGORDGZLOOVKRUWHQWKHSURGXFW¶VOLIHVR
SOHDVHDWWDFKDQDX[LOLDU\ UHOD\,IWKHRXWSXWRSHUDWLRQIUHTXHQF\LVKLJKVHOHFWLQJ D665GULYH
output type is recommended.
[Proportionate cycles] Relay output: 30 seconds or more, SSR drive output: 1 second or more
Ɣ,I\RXVHOHFWHGWKHYHUVLRQZLWK&7XVHDFRPPRQSRZHUOLQHIRUWKHKHDWHUDQGWKHFRQWUROOHU
Ɣ:KHQLQGXFWLYHORDGVVXFKDVPDJQHWLFRSHQLQJFORVLQJHTXLSPHQWHWFDVUHOD\RXWSXWHTXLSPHQW
are connected, use of a surge absorber is recommended in order to protect the contacts against
opening/closing surges and to ensure long-term use.
5HFRPPHQGHGVSHFL¿FDWLRQIRUWKHVXUJHDEVRUEHU
Voltage Nominal varistor voltage
100 V 240 V
200 V 470 V
$WWDFKPHQWSRVLWLRQEHWZHHQWKHUHOD\FRQWURORXWSXWFRQWDFWV
13
16
17
18
14
15
7
8
10
11
12
9
1
2
4
5
6
3
(Example)
.H\2SHUDWLRQ&DXWLRQV(UURU2SHUDWLRQV
Ɣ7KHDODUPIXQFWLRQGRHVQRWZRUNSURSHUO\ZKHQDQHUURUWDNHVSODFHXQOHVVWKHVHWWLQJVDUHPDGH
FRUUHFWO\$OZD\VYHULI\LWVVHWWLQJEHIRUHRSHUDWLRQ
Ɣ,I WKH LQSXWZLULQJEUHDNVWKHGLVSOD\ ZLOO UHDG8888RU//// :KHQ UHSODFLQJWKHVHQVRU
DOZD\VWXUQWKHSRZHU2))
2WKHUV
Ɣ3OHDVHGRQRWZLSHWKHHTXLSPHQWZLWKRUJDQLFVROYHQWVVXFKDVDOFRKRORUEHQ]HQHHWF,IZLSLQJ
is necessary, use a neutral cleaning agent.
Ɣ'RQRWXVHPRELOHSKRQHVQHDUWKLVHTXLSPHQWZLWKLQFP2WKHUZLVHDPDOIXQFWLRQPD\UHVXOW
Ɣ7URXEOHPD\RFFXULIWKHHTXLSPHQWLVXVHGQHDUDUDGLR79RUZLUHOHVVGHYLFH
Ɣ7KLVHTXLSPHQWVKRXOGEHWUHDWHGDVDQLQGXVWULDOZDVWHZKHQLWLVGLVSRVHGRI
)RU3URSHU8VDJH
Please con¿rm that the model delivered matches your order.
0RGHO6SHFL¿FDWLRQVSDJH
Terminal connections diaJram
"4 WirLQJSDJH
&KDQJLQJVHWvalue
Basic Operation Methods
Parameter List
Input/Output/Control
"5 Display and OperDWLRQVSDJH
"5 Display and OperDWLRQVSDJH
ParDPHWHU/LVWSDJHWR
)XQFWLRQVSDJH
6HWWLQJRILQSXWVHQVRUDQGLQSXWrDQJH
6HOHFWLQJFRQWUROPHWKRG
&RQWUROOLQJWKURXJKDXWRWXQLQJ
WRPDWLFVHWWLQJSDrameters
,QSXW6HWWLQJSDJH
&RQWURO6HWWLQJSDJH
AXWRWXQLQJSDJH
)X]]\3,'&RQWURO6HOIWXQLQJ&RQWUROSDJH
Display durLQJHTXLSPHQWHUURU
(UURU,QGLFDWLRQVSDJH
([WHrnal dimensions
Panel cut dimensions
0RXQWLQJWKHSDQHO
,QVWDOODWLRQDQG0RXQWLQJSDJH
&RQ¿rmation of model code
2
Wiring Connection
3 Display and Operations
4 Parameter List
5 Functions of the Temperature Controller
Turn Power On
6 Advanced Usage
7 Error Indications
Operation
1 Installation and Mounting
Caution
:DLWPLQXWHVIRUWKHFRQWUROOHUWRVWDELOL]HGWKHUPDOO\2SHUDWLRQVVXFKDV
measurements should be taken after the equipment has been on for 30 minutes
or more.
- 2 -