6SHFL¿FDWLRQV
3RZHUVXSSO\YROWDJH WR9$&+]9'&$&+]
3RZHUFRQVXPSWLRQ 10 VA MAX. (100 to 240 V AC), 5 VA MAX. (24 V DC/AC)
Control output Relay contact output
1 SPST contact, 250 V AC/30 V DC, 3A (resistive load)
1 SPDT contact, 250 V AC/30 V DC, 5 A (resistive load)
SSR drive output (voltage pulse output)
ON voltage: 12 V DC (10.7 to 13.2V DC)
2))YROWDJH9'&RUORZHU
0D[LPXPFXUUHQWP$'&
/RDGUHVLVWDQFHȍ0,1
Current output
0 to 20 mA DC/4 to 20 mA DC
$FFXUDF\)6
/RDGUHVLVWDQFHȍ0$;
Voltage outputt
0 to 5 V DC/1 to 5 V DC/0 to 10 V DC/2 to 10 V DC
$FFXUDF\)6
/RDGUHVLVWDQFHNȍ0,1
Process value input Accuracy
7KHUPRFRXSOHLQSXWHLWKHU&GLJLWRUGLJLWRILQGLFDWHG
YDOXHZKLFKHYHULVODUJHU
*H[FHSW7KHUPRFRXSOH%WR&QRDFFXUDF\DVVXUDQFH
7KHUPRFRXSOH5WR&&GLJLW
2WKHUWKHUPRFRXSOHVWR&&GLJLW
57'HLWKHU&GLJLWRUGLJLWZKLFKHYHULVODUJHU
P9LQSXWYROWDJHLQSXWFXUUHQWLQSXW)6GLJLW
Alarm output 5HOD\FRQWDFWRXWSXW$/WR$/
1 SPST contact, 250 V AC/30 V DC, 1A (resistive load)
Digital input 1XPEHURILQSXWVXSWRSRLQWVIRUWKHPRWRUL]HGYDOYHFRQWUROW\SH
Contact capacity: 5 V DC, 2 mA (per point)
,QSXWSXOVHZLGWKPV0$;
21MXGJPHQW9'&RUORZHU
2))MXGJPHQW9'&RUKLJKHU
Transfer output 0 to 20 mA DC/4 to 20 mA DC
0 to 5 V DC/1 to 5 V DC/ 0 to 10 V DC/2 to 10 V DC)
Transfer data: PV, SV, DV, MV
$FFXUDF\)6)6FXUUHQWRXWSXWIRUP$RUORZHU
/RDGUHVLVWDQFHȍ0$;FXUUHQWNȍ0,1YROWDJH
Remote SV input 0 to 5 V DC/1 to 5 V DC/0 to 10 V DC/2 to 10 V DC
WRP$'&WRP$'&DQH[WHUQDOUHVLVWDQFHRIȍLVUHTXLUHG
for current input)
Current transformer (CT) input Single phase current transformer: 1 point, for 1 to 30 A/20 to 100 A
0RWRUL]HGYDOYHFRQWURORXWSXW 6367FRQWDFWî>ZLWKRXWLQWHUORFNFLUFXLW@9$&9'&$UHVLVWLYH
load)
Communication function RS-485 interface
&RPPXQLFDWLRQPHWKRG+DOIGXSOH[ELWVHULDODV\QFKURQRXVFRPPXQLFDWLRQ
Transmission rate: 9600 bps, 19200 bps, 38400 bps, 115400 bps
Protocol: Modbus RTU compatible
Transmission distance: Up to 500 m (total connection length)
Connectable units: 31 units MAX.
/RDGHULQWHUIDFH 77//HYHO
Connection method: dedicated cable
&RPPXQLFDWLRQPHWKRG+DOIGXSOH[ELWVHULDODV\QFKURQRXVFRPPXQLFDWLRQ
Transmission rate: 38400 bps, no parity
Protocol: Modbus RTU compatible
Storage temperature and humidity -20 to 60°C, 90%RH or less (no condensation)
Operating temperature and humidity -10 to 50°C, 90%RH or less (no condensation)
Altitude up to 2000 m
Recommended fuse
9$&$77LPH/DJIRUWR9$&3RZHUVXSSO\
9'&9$&$77LPH/DJIRU9'&9$&3RZHUVXSSO\
Service life Service life: 10 years (at an average temperature of 25°C)
7KHOLIHLVVKRUWHQHGE\KDOIZKHQWKHWHPSHUDWXUHULVHVE\&$UUKHQLXV
ODZ,I\RXXVHWKHFRQWUROOHULQVLGHDFDELQHWRUWKHOLNHSOHDVHQRWHWKDWWKH
ambient temperature can rise.
/LPLWHGZDUUDQW\
6FRSHRIZDUUDQW\
,IPDOIXQFWLRQRFFXUVLQ WKH SHULRGRIZDUUDQW\GXH WR )XML(OHFWULFWKHPDOIXQFWLRQLQJ SDUWV DUH
H[FKDQJHGRUUHSDLUHGIRUIUHH
+RZHYHULQWKHFDVHZKHUHDQHQJLQHHUQHHGVWRYLVLW\RXUSODFHIRUUHSODFHPHQWRUUHSDLU\RXZLOO
be charged our call out fee.
3OHDVHQRWHWKDWZH FDQQRW SURYLGHFRPPLVVLRQLQJDQGRUUHDGMXVWPHQW IRU ZKROHV\VWHPLQFOXGLQJ
our product at repair or replacement of failed parts.
7KHZDUUDQW\GRHVQRWDSSO\WRWKHIROORZLQJFDVHV
(1) The malfunction occurs due to inappropriate conditions, environment, handling or usage that is
QRWLQVWUXFWHGLQDFDWDORJLQVWUXFWLRQERRNRUXVHUVPDQXDO
(2) The malfunction is caused by the factors that do not originate in the purchased or delivered
product.
7KHPDOIXQFWLRQ LV FDXVHGE\RWKHUGHYLFHVRU VRIWZDUH GHVLJQWKDWGRHVQRW RULJLQDWH LQ)XML
Electric products.
7KHPDOIXQFWLRQRFFXUVGXHWRDQDOWHUDWLRQRUUHSDLUWKDWLVQRWSHUIRUPHGE\)XML(OHFWULF
7KH PDOIXQFWLRQRFFXUVEHFDXVHWKHH[SHQGDEOH SDUWV OLVWHGLQDQLQVWUXFWLRQ ERRN RU
FRQQHFWDEOHZHUHQRWPDLQWDLQHGQRUH[FKDQJHGLQDQDSSURSULDWHPDQQHU
7KHPDOIXQFWLRQ RFFXUV GXH WRIDFWRUVWKDWZHUHQRWIRUHVHHDEOHE\WKH SUDFWLFDO DSSOLFDWLRQ RI
science and technology at the time of purchase or delivery.
(7) The malfunction occurs because the product is used for an unintended purpose.
7KHPDOIXQFWLRQRFFXUVGXHWRDGLVDVWHURUQDWXUDOGLVDVWHUWKDW)XML(OHFWULFLVQRWUHVSRQVLEOH
for.
([FOXVLRQRIOLDELOLW\IRUORVVRIRSSRUWXQLW\
5HJDUGOHVVRIWKHWLPHSHULRG RI WKHRFFXUUHQFHWKH DPRXQW RIFRPSHQVDWLRQDVVXPHGE\)XML
(OHFWULFIRUGDPDJHH[FOXGLQJZKLFK LV FDXVHGE\LQWHQWLRQDODFWV RU DFWVRIJURVVQHJOLJHQFHRU
LOOHJDODFWE\)XML(OHFWULFVKDOOQRWH[FHHGWKHDPRXQWVWLSXODWHGLQWKHFRQWUDFWZLWKWKHFXVWRPHU
)XML(OHFWULFLVQRWOLDEOH IRU WKHGDPDJHWRSURGXFWV WKDW ZHUHQRWPDQXIDFWXUHGE\)XML (OHFWULF
incidental damages or consequential damages, or damage caused due to special situations
UHJDUGOHVVRIZKHWKHULWZDVIRUHVHHDEOHRUQRWRUSDVVLYHGDPDJHVVXFKDVRSSRUWXQLW\ORVVRUORVW
SUR¿WVRIWKHSXUFKDVHU
3. Scope of application
Ɣ7KLVHTXLSPHQWPXVWEHXVHGXQGHUWKHIROORZLQJFRQGLWLRQV
-
The use of the equipment incurs no risk of a serious accident even if a failure or malfunction
occurs on the equipment, and in case of product failure or malfunction, safety measures such as
redundant design, prevention of malfunction, fail safe setting, foolproof mechanism are provided
outside of the equipment by the user.
Ɣ7KHSURGXFWGHVFULEHG LQ WKLVGRFXPHQWLVGHVLJQHG DQG PDQXIDFWXUHGDVDJHQHUDOSXUSRVH
products for general industrial applications.
Ɣ7KHZDUUDQW\GRHVQRWDSSO\WRWKHIROORZLQJFDVHV
)RUWKHXVHQRWGHVFULEHGLQRUEH\RQGWKHFRQGLWLRQVRUHQYLURQPHQWVSHFL¿HGLQWKHLQVWUXFWLRQ
manual or the user manual,
)RUWKHXVH ZKLFK KDVODUJHLQIOXHQFHRQ SXEOLFLW\ LQFOXGLQJQXFOHDUSRZHUDQG RWKHU SRZHU
JHQHUDWLRQJDVDQGRUZDWHU
)RUWKHXVHLQ ZKLFK VDIHW\LVHVSHFLDOO\UHTXLUHG EHFDXVH LWPD\VHULRXVO\DIIHFWUDLOURDGV
vehicles, combustion equipment, medical equipment, entertainment devices, safety equipment,
defense equipment, and/or human lives and property.
+RZHYHUZHZLOOVWXG\ WKH SRVVLELOLW\RIDSSOLFDWLRQRIWKH HTXLSPHQWIRUWKHDERYHXVHLIWKHXVHU
limits the usage of it and agrees to require no special quality. Please consult us.
- 24 -
Issued in May, 2015
Rev August, 2017

Other manuals for Fuji Electric Micro-Controller X Socket type

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fuji Electric Micro-Controller X Socket type and is the answer not in the manual?

Fuji Electric Micro-Controller X Socket type Specifications

General IconGeneral
BrandFuji Electric
ModelMicro-Controller X Socket type
CategoryTemperature Controller
LanguageEnglish

Related product manuals