¢ DIP switch setting
SW101-Switch 1: Drainage function setting
Switch 1 Drainage function Factory setting
ON Disabled
OFF Enabled
SW101-Switch 2: Auto louver grille setting
When Auto louver grille kit (optional parts) is attached, set to “Enabled”.
Switch 2 Auto louver grille setting Factory setting
ON Enabled
OFF Disabled
SW101-Switch 3: Fan delay setting
When the indoor unit is stopped while operating in conjunction with auxiliary heater, the indoor
unit fan operation will continue for 1 minute.
Switch 3 Fan delay Factory setting
ON Enabled
OFF Disabled
- 186 -
16-2. Slim duct type indoor unit (setting by DIP switch) 16. Function settings