Push switch onoutdoor
unit PCB
00 Connected number of indoor unit The number of the communicating unit is displayed
01
Software version :
[ ] [ ] [ ] [ ] [ ] displays by five items
It skips when there is no suffix
02 Software version of INV PCB
03 Software version of communication PCB
Operation of
each part
10 Rotational speed of outdoor unit fan motor The rotational speed of the outdoor unit fan motor is displayed
[ rpm ]
11 Rotational speed of INV compressor The rotational speed of the compressor is displayed
[ rps ]
12 Current value of INV compressor Current value of INV compressor is displayed
[ A ]
14 Pulse of EEV1 Pulse of EEV1 is displayed
[ pls ]
15
Pulse of EEV2 Pulse of EEV2 is displayed
[ pls ]
Time guard 20 Accumulated current time Accumulated current time is displayed
[ 10 hour ]
21 INV compressor accumulated time
[ Cooling ]
Accumulated time is displayed in the cooling operation of the
INV compressor
[ 10 hour ]
22 INV compressor accumulated time
[ Heating ]
Accumulated time is displayed in the heating operation of the
INV compressor
[ 10 hour ]
Refrigerant
cycle data 1
30 Information on Thermistor 1
( INV compressor discharge temperature )
The value of the Thermistor 1 is displayed
32
Information on Thermistor 3
( Outdoor temperature )
The value of the Thermistor 3 is displayed
33 Information on Thermistor 4
( Suction temperature )
The value of the Thermistor 4 is displayed
34
Information on Thermistor 5
( Heat-exchanger temperature )
The value of the Thermistor 5 is displayed
36
Information on Thermistor 7
( Liquid temperature 2 )
The value of the Thermistor 7 is displayed
37
Information on Thermistor 8
( Sub-cool heat-exchanger inlet temperature )
The value of the Thermistor 8 is displayed
38 Information on Thermistor 9
( Sub-cool heat-exchanger outlet temperature )
The value of the Thermistor 9 is displayed
39 Information on Thermistor 10
( INV compressor temperature )
The value of the Thermistor 10 is displayed
50
Information on pressure sensor 1
( High pressure sensor )
The value of the pressure sensor 1 is displayed
[ MPa ] or [ psi ]
51
Information on pressure sensor 2
( Low pressure sensor )
The value of the pressure sensor 2 is displayed
[ F1 ]
Monitor mode
Setting Mode
ITEM
CODE No.
Information contents
Refrigerant
cycle data 2
Device and
system
Software version of outdoor unit
Classification
01-15
1-4 Field Setting And Monitor Mode List for Outdoor unit
[ MPa ] or [ psi ]
[°C ] or [°F ]
[°C ] or [°F ]
[°C ] or [°F ]
[°C ] or [°F ]
[°C ] or [°F ]
[°C ] or [°F ]
[°C ] or [°F ]
[°C ] or [°F ]