Inverter Error
YES
NO
OK
Check Point 1-2 : Noise, momentary open, voltage drop
Inverter PCB
Error information received from Inverter PCB
1. Noise, momentary open, voltage drop. 2. Power supply to Filter PCB (INV) to Inverter PCB
wiring disconnection, open 3. Filter PCB ( INV) defective 4. Inverter PCB defective
Check if temporary voltage drop was not generated.
Check if momentary open was not generated.
Check if ground is connection correctly or there are no related cables near the
power line.
Check Point 2 : Check the wiring (Power supply to Filter PCB (INV) to Inverter PCB)
Connector and wiring connection state check
Cable open check
Check resistance of cement resistor
Check Point 1-1 : Turn the power
on again.
Error displayed again?
Check Point 3 : Check Cement resistor
Indoor Unit : Operation LED 9 times Flash, Timer LED 15 Times Flash,
Filter LED Continuous Flash.
Outdoor Unit : E. 63. 1
Error Code : 63
04-29
Trouble shooting 21
Indicate or Display:
Detective Actuators:
Detective details:
OUTDOOR UNIT Error Method:
Forecast of Cause :
5. Cement Resistor Open circuit
OK
Check Filter PCB (INV) and Inverter PCB.
(Refer to "Sarvise Parts Information 5")
Check Point 4 : Check Filter PCB (INV) and Inverter PCB
If the circuit of both terminal was open circuit, exchange the Resistor
Correct resistance value: 5.3 - 6.0 Ohm