- 128 -
MULTI TYPE
4 rooms type
13. Function settings
To adjust the functions of this product according to the installation environment, various types of
function settings are available.
NOTE: Incorrect settings can cause a product malfunction.
13-1. Indoor unit (setting by jumper wire)
NOTE: This setting is necessary only for slim duct type.
Component location
Jumper wire setting
Drainage function setting (JM1)
Auto louver grille setting (JM2)
When optional Auto louver grille kit is attached, set this setting to "Valid".
Fan delay setting (JM3)
JM1 Function Factory setting
Connect Enable
Disconnect Disable
JM2 Function Factory setting
Connect Disable
Disconnect Enable
JM3 Function Factory setting
Connect Disable
Disconnect Enable
JM1
JM2
JM3