EasyManua.ls Logo

Fujitsu AOU36RLXFZH - Safety Devices

Fujitsu AOU36RLXFZH
258 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- 232 -
OUTDOOR UNIT
AOU36RLXFZH
12. Safety devices
Type of protection Protection form
Model
AOU36RLXFZH
Circuit protection
Current fuse
(PCB)
250 V, 10 A
250 V, 5 A
400 V, 5 A
250 V, 3.15 A
Protector
(PCB)
500 V, 45 A
Fan motor protection Thermal protection program
Activate
239 ±2 7 °F
(115 ± 15 °C)
Fan motor stop
Reset
158 °F
(70 °C)
Fan motor restart
Compressor protection
Thermal protection program
(Compressor temp.)
Activate
226 °F
(108 °C)
Compressor stop
Reset
176 °F
(80 °C)
Compressor restart
Thermal protection program
(Discharge temp.)
Activate
230 °F
(110 °C)
Compressor stop
Reset
After 3 minutes
and 230 °F (110 °C) less than
Compressor restart