- 239 -
OUTDOOR UNIT
AOU36RLXFZH
4. After the check run is completed, results will be displayed. Fill the displayed results in the result
table accordingly.
If the connection is correct (Example: When 4 indoor units are connected)
After the number of connected units are displayed, the LED for each unit will light up in order
from A to D.
If the connection is incorrect (Example: When connection of B and C of the 4 units are
reversed)
After the number of connected units are displayed, B and C will light up in reverse.
NOTES:
Automatic wiring correction will not be completed if the power supply is disconnected while
displaying the results. To confirm the automatic wiring correction, be sure to carry out step 5.
If frost is formed on the outdoor unit while displaying the results, automatic defrost function
will be operated. Proceed to step 5 after the defrost function is finished.
(2-blink)
(7 sec.)
(7 sec.)
(7 sec.)
(7 sec.)
FEDC
MONITOR
ERROR
BA
POWER
MODE
FEDC
MONITOR
ERROR
BA
POWER
MODE
(7 sec.)
(7 sec.)
(7 sec.)
(7 sec.)
(2-blink)