- 35 -
MULTI TYPE
4 rooms type
Pattern B
1. Modify the remote controller cable as follows:
Use a tool to cut off the terminal on the end of the remote controller cable and then remove
the insulation from the cut end of the cable as shown in following figure.
Connect the remote controller cable and connecting cable as shown in following figure.
Be sure to insulate the connection between the cables.
2. Connect the remote controller cable.
Connect the cable made in step 1. to the terminal (*1) of optional communication kit.
Connect the cable from the terminal (*2) of communication kit to the indoor unit PCB.
*1: CNC01 (for ASU7/9/12/15RLF1: UTY-XCBXZ2)
*2: CND01 (for ASU7/9/12/15RLF1: UTY-XCBXZ2)
13/16 in.
(20 mm)
Remote controller cable
Connecting
cable
White
Red
White
Red
Black
Insulated
connection
Black
Remote controller cable
Connecting cable Terminal
(*1)
Terminal
(*2)
Communication kit
Indoor unit PCB