6. SYSTEM DESIGN
EXAMPLE 3
21 3
f g h
c
Outdoor unit
Branch box
Indoor unit Indoor unit Indoor unit
(24000Btu) (18000Btu) (7000Btu)
System configuration
(Indoor units)
12345678
Total Capacity
(Btu)
Model name ASU24 ASU18 ASU7
49000
Capacity (Btu) 24000 18000 7000
Capacity ratio
(Total indoor unit capacity) / (Total outdoor unit capacity)
= (49000) / (48000) = 102.1% (Within 80% to 130%)
Selection of separation tube
Model Q'ty
UTP-SX248A None
Selection of branch box
Model Q'ty
UTP-PU03A (primary) 1
UTP-PU03B (secondary) None
Selection of pipe size
abcdefg
Liquid pipe size
in. (mm)
3/8
(9.52)
1/4
(6.35)
1/4
(6.35)
Gas pipe size
in. (mm)
5/8
(15.88)
5/8
(15.88)
1/2
(12.70)
Pipe length
ft (m)
148
(45)
39
(12)
39
(12)
hijklm
Liquid pipe size
in. (mm)
1/4
(6.35)
Gas pipe size
in. (mm)
3/8
(9.52)
Pipe length
ft (m)
49
(15)
- (06 - 22) -
SYSTEM
DESIGN
SYSTEM
DESIGN