8) Room temperature sensor switching (Aux.)
To use the temperature sensor on the wired remote controller only, change the setting to "Wired re-
mote controller" (01).
This function will only work if the function setting 42 is set at "Both" (01).
When the setting value is set to "Both" (00), more suitable control of the room temperature is possi-
ble by setting function setting 30 and 31 too.
Function number Setting value Setting description Factory setting
48
00 Both
01 Wired remote controller
9) Indoor unit fan control for energy saving for cooling
Enables or disables the power-saving function by controlling the indoor unit fan rotation when the
outdoor unit is stopped during cooling operation.
Function number Setting value Setting description Factory setting
49
00 Disable
01 Enable
00: When the outdoor unit is stopped, the indoor unit fan operates continuously following the setting
on the remote controller.
01: When the outdoor unit is stopped, the indoor unit fan operates intermittently at a very low speed.
- 28 -
11-1. Function settings by using remote controller 11. Function settings
WALL MOUNTED
ASYG09-14KHCA
WALL MOUNTED
ASYG09-14KHCA

Table of Contents

Other manuals for Fujitsu AOYG09KHCAN

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG09KHCAN and is the answer not in the manual?

Fujitsu AOYG09KHCAN Specifications

General IconGeneral
BrandFujitsu
ModelAOYG09KHCAN
CategoryAir Conditioner
LanguageEnglish

Related product manuals