Page #142 background imageLoading...
Page #142 background image
- 136 -
OUTDOOR UNIT
AOYG12-54LB
4. Press the ENTER switch button (SW3).
5. Press the SELECT switch button (SW2), and adjust the LED lamps as shown below.
6. Press the ENTER switch button (SW3) and fix it.
7. To return to “Operating status display (Normal operation)”, press the EXIT switch button
(SW4).
NOTE: When pressed number is lost during setting, you must redo the setting procedure. Return to
“Operation status display (Normal operation)” by pressing the EXIT switch button once, and
restart from the beginning of the setting procedure.
(L2) (L3)
LOW NOISE
PEAK CUT
MODE
Sign “ ”: Lights on
100 % of rated input ratio
75 % of rated input ratio
50 % of rated input ratio
0 % of rated input ratio
Blink
Blink Blink
Blink
Blink
PEAK CUT
(L4) (L5) (L6)
100 % of rated input ratio
75 % of rated input ratio
50 % of rated input ratio
0 % of rated input ratio
PEAK CUT
(L4) (L5) (L6)