- 56 -
DUCT TYPE
ARYG12-54LHTBP
10. External input and output
10-1. External input
“Operation/Stop” mode or "Forced stop" mode can be selected with function setting of indoor unit.
A twisted pair cable (22AWG) should be used. Maximum length of cable is 150 m.
The wire connection should be separate from the power cable line.
Indoor unit
Indoor unit functions such as Operation/Stop can be done by using indoor unit terminals.
*1: The switch can be used on the following condition: DC 12 V to 24 V, 1 mA to 15 mA.
PCB External input External output Connector Input select
Input
signal
External
connect kit
(Optional parts)
Indoor unit
Operation/Stop
Forced stop
- Terminal Dry contact Edge -
-
Operation status
CN47 - - UTY-XWZXZG
Error status
Indoor unit fan
operation status
External heater
output
External
input and
output
(UTY-XCSX)
Operation/Stop
-
Input 1/
Input 2
Dry contact/
Apply voltage
Edge/
Pulse
-
Forced
thermostat off
Input 1 Edge
-
Operation status
Output 1
Output 2
Output 3
-- -
Error status
Indoor unit
status
External heater
output
Terminal
(Ext.in)
CN65
(Ext.in/out PCB)
CN47
(Ext.out)
Rotary switch
SW2
SW1
Fig. External input and output PCBFig. Indoor unit PCB
1
2

Terminal
PCB

Table of Contents

Other manuals for Fujitsu AOYG18LBCA

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AOYG18LBCA and is the answer not in the manual?

Fujitsu AOYG18LBCA Specifications

General IconGeneral
BrandFujitsu
ModelAOYG18LBCA
CategoryAir Conditioner
LanguageEnglish

Related product manuals