MODEL: ASYG18LFCA
Outdoor temperature
Indoor temperature (°CDB / °CWB)
18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0
(°CDB) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
-10.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
-5.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
0.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
5.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
10.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
15.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
20.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
25.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
30.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
35.0 4.18 2.75 5.03 3.35 5.69 3.82 6.42 4.94 6.86 5.41 7.07 6.19
40.0 3.96 2.46 4.76 3.00 5.38 3.42 6.07 4.43 6.49 4.84 6.69 5.55
46.0 3.73 2.19 4.49 2.67 5.08 3.04 5.73 3.94 6.12 4.31 6.31 4.93
MODELS: ASYG24LFCA and ASYG24LFCC
Outdoor temperature
Indoor temperature (°CDB / °CWB)
18.0 / 12.0 21.0 / 15.0 23.0 / 16.0 27.0 / 19.0 29.0 / 21.0 32.0 / 23.0
(°CDB) TC SHC TC SHC TC SHC TC SHC TC SHC TC SHC
-10.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
-5.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
0.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
5.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
10.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
15.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
20.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
25.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
30.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
35.0 5.60 3.34 6.73 4.08 7.61 4.65 8.59 6.01 9.18 6.58 9.47 7.53
40.0 5.30 2.99 6.37 3.65 7.20 4.16 8.13 5.38 8.69 5.89 8.96 6.75
46.0 5.00 2.66 6.01 3.25 6.79 3.70 7.67 4.79 8.19 5.24 8.45 6.00
NOTES:
• TC: Total Capacity (kW), SHC: Sensible Heat Capacity (kW)
• Values mentioned in the table are based on the following conditions:
– Pipe length: 5 m, Height difference: 0 m [Outdoor unit—Indoor unit]
- 299 -
OUTDOOR UNIT
AOYG36LBLA5