¢ Floor/Ceiling type
MODEL: ABYG14LVTA
Outdoor temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 22.0 24.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 4.11 3.92 3.76 3.68 3.60
-10.0 -11.0 4.60 4.38 4.24 4.15 4.06
-5.0 -7.0 5.11 4.90 4.72 4.65 4.58
0.0 -2.0 5.63 5.42 5.20 5.07 4.95
5.0 3.0 6.35 6.05 5.60 5.41 5.23
7.0 6.0 6.48 6.09 5.60 5.34 5.08
10.0 8.0 6.43 6.05 5.60 5.34 5.08
15.0 10.0 6.42 6.01 5.60 5.36 5.12
20.0 15.0 6.37 5.97 5.60 5.38 5.16
24.0 18.0 6.29 5.93 5.60 5.50 5.40
MODEL: ABYG18LVTB
Outdoor temperature
Indoor temperature (°CDB)
16.0 18.0 20.0 22.0 24.0
(°CDB) (°CWB) TC TC TC TC TC
-15.0 -16.0 5.29 5.04 4.83 4.73 4.63
-10.0 -11.0 5.91 5.64 5.45 5.34 5.22
-5.0 -7.0 6.57 6.30 6.07 5.98 5.89
0.0 -2.0 7.24 6.96 6.69 6.52 6.36
5.0 3.0 8.16 7.78 7.20 6.96 6.72
7.0 6.0 8.33 7.83 7.20 6.86 6.53
10.0 8.0 8.27 7.78 7.20 6.87 6.53
15.0 10.0 8.25 7.73 7.20 6.89 6.59
20.0 15.0 8.19 7.67 7.20 6.92 6.64
24.0 18.0 8.09 7.62 7.20 7.07 6.95
NOTES:
TC: Total Capacity (kW)
Values mentioned in the table are based on the following conditions:
Pipe length: 5 m, Height difference: 0 m [Outdoor unit—Indoor unit]