Outdoor Unit Model Information Error
YES
NO
Check Point 1-2 : External cause
Outdoor unit Main PCB
Access to EEPROM failed due to some cause after outdoor unit started.
1. External cause (Noise, temporary open, voltage drop) 2. Main PCB failure
Check if temporary voltage drop was not generated.
Check if momentary open was not generated.
Check if ground is connected correctly or there are no related cables near the
power line.
Check Point 2 : Replace Main PCB
Change Main PCB, and execute the check operation again.
Check Point 1-1 : Turn the power
on agaun.
Error displayed again?
Indoor Unit : Operation LED 6 times Flash, Timer LED 2 Times Flash,
Economy LED Continuous Flash.
Outdoor Unit : E. 62. 1
Error Code : 62
Trouble shooting 14
Indicate or Display:
Detective Actuators:
Detective details:
OUTDOOR UNIT Error Method:
Forecast of Cause :
02-30