EasyManua.ls Logo

Fujitsu aoyg45lbt8 - User Manual

Fujitsu aoyg45lbt8
21 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
EnglishDeutschFrançaisEspañolItalianoEλληvIkάPortuguêsРусскийTϋrkçe
En-1
AIR CONDITIONER
OUTDOOR UNIT
PART NO. 9379069366
INSTALLATION MANUAL
INSTALLATIONSANLEITUNG
MANUEL D'INSTALLATION
MANUAL DE INSTALACIÓN
MANUALE D'INSTALLAZIONE
ΕΓΧΕΙΡΙΔΙΟ ΕΓΚΑΤΑΣΤΑΣΗΣ
MANUAL DE INSTALAÇÃO
РУКОВОДСТВО ПО УСТАНОВКЕ
MONTAJ KILAVUZU
For authorized personnel only.
Nur für autorisiertes Personal.
Pour le personnel agréé uniquement.
Solo para personal autorizado.
Ad uso esclusivo del personale autorizzato.
Για εξουσιοδοτημένο προσωπικό σέρβις.
Apenas para técnicos autorizados.
Для уполномоченного персонала.
Yetkili servis personeli içindir.
9379069366_IM.indb 1 15/11/2555 11:17:46
Question and Answer IconNeed help?

Do you have a question about the Fujitsu aoyg45lbt8 and is the answer not in the manual?

Summary

Installation Manual Overview

R410 A Refrigerant Safety Caution

Highlights R410A refrigerant safety and the need for qualified personnel for installation.

Safety Precautions

General Warning for Safety Precautions

Critical procedures that could lead to death or serious injury if performed incorrectly.

General Caution for Safety Precautions

Procedures that, if performed incorrectly, might result in personal harm or property damage.

About the Product

R410 A Refrigerant Handling Precautions

Key considerations for R410A refrigerant, including pressure and tool differences.

Installation Work

Installation Location Selection Guidelines

Crucial safety and operational advice for choosing an outdoor unit installation site.

Outdoor Unit Installation Details

Pipe Installation

Flare Connection for Refrigerant Pipes

Making secure flare connections for refrigerant pipes, including material and welding precautions.

Pipe Connection and Flaring Details

Connecting Refrigerant Pipes to Valves

Instructions for connecting refrigerant pipes to outdoor unit valves, emphasizing centering and torque.

Electrical Wiring

Electrical Wiring Safety Precautions

Critical safety warnings and guidelines for performing electrical wiring work.

Connecting Unit Wiring Terminals

Instructions for stripping wires and connecting them to terminal blocks securely.

Wiring Connections and Securing

Pipe Installation II

Refrigerant Pipe Sealing Test Procedure

Procedure for performing a sealing test using nitrogen gas to detect refrigerant leaks.

Vacuum Process for Refrigerant System

Steps for evacuating the refrigerant system using a vacuum pump.

Additional Refrigerant Charging Calculation

Instructions and calculations for adding refrigerant based on pipe length and diameter.

Pipe Installation II Details

Refrigerant Recovery Method

Steps for safely recovering refrigerant using specialized equipment.

Field Setting

Field Setting Procedure

Test Operation

Pre-Check Run Confirmation Items

Critical checks required before starting the system's check run.

Check Run Operation Procedure

Step-by-step guide for initiating and monitoring the system's check run.

Test Operation Details

Pre-Test Run Check Items

Essential checks to perform before initiating the test run operation.

Test Run Configuration and Execution

Instructions for configuring and executing test run modes (cooling/heating).

Indoor Unit Operation Confirmation

Summary

Installation Manual Overview

R410 A Refrigerant Safety Caution

Highlights R410A refrigerant safety and the need for qualified personnel for installation.

Safety Precautions

General Warning for Safety Precautions

Critical procedures that could lead to death or serious injury if performed incorrectly.

General Caution for Safety Precautions

Procedures that, if performed incorrectly, might result in personal harm or property damage.

About the Product

R410 A Refrigerant Handling Precautions

Key considerations for R410A refrigerant, including pressure and tool differences.

Installation Work

Installation Location Selection Guidelines

Crucial safety and operational advice for choosing an outdoor unit installation site.

Outdoor Unit Installation Details

Pipe Installation

Flare Connection for Refrigerant Pipes

Making secure flare connections for refrigerant pipes, including material and welding precautions.

Pipe Connection and Flaring Details

Connecting Refrigerant Pipes to Valves

Instructions for connecting refrigerant pipes to outdoor unit valves, emphasizing centering and torque.

Electrical Wiring

Electrical Wiring Safety Precautions

Critical safety warnings and guidelines for performing electrical wiring work.

Connecting Unit Wiring Terminals

Instructions for stripping wires and connecting them to terminal blocks securely.

Wiring Connections and Securing

Pipe Installation II

Refrigerant Pipe Sealing Test Procedure

Procedure for performing a sealing test using nitrogen gas to detect refrigerant leaks.

Vacuum Process for Refrigerant System

Steps for evacuating the refrigerant system using a vacuum pump.

Additional Refrigerant Charging Calculation

Instructions and calculations for adding refrigerant based on pipe length and diameter.

Pipe Installation II Details

Refrigerant Recovery Method

Steps for safely recovering refrigerant using specialized equipment.

Field Setting

Field Setting Procedure

Test Operation

Pre-Check Run Confirmation Items

Critical checks required before starting the system's check run.

Check Run Operation Procedure

Step-by-step guide for initiating and monitoring the system's check run.

Test Operation Details

Pre-Test Run Check Items

Essential checks to perform before initiating the test run operation.

Test Run Configuration and Execution

Instructions for configuring and executing test run modes (cooling/heating).

Indoor Unit Operation Confirmation

Fujitsu aoyg45lbt8 Specifications

General IconGeneral
BrandFujitsu
Modelaoyg45lbt8
CategoryAir Conditioner
LanguageEnglish

Related product manuals