EasyManua.ls Logo

Fujitsu ARTG54LHTC - Safety Devices

Fujitsu ARTG54LHTC
66 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
- (02 - 16) -
OUTDOOR UNIT
AOTG54LCTL
OUTDOOR UNIT
AOTG54LCTL
SAFETY DEVICES13.
Protection form
Model
AOTG54LC
Circuit protection
Current fuse (Main PCB) 250V 3.15A
Current fuse (Filter PCB)
"250V 10A" × 2
250V 30A
250V 3.15A
Fan motor protection Thermal protector
OFF:150±15°C
ON:120±15°C
Compressor
protection
Thermal protection program
(Compressor temp.)
OFF:110°C
ON:80°C
Thermal protection program
(Discharge temp.)
OFF : 115°C
ON : After 7 minutes
High pressure
protection
Thermal protection program
(Heat exchanger temp.)
Cooling
OFF : 68°C
ON : 63°C
Pressure sensor Heating
OFF:4.1MPa
ON : After 3 minutes
Low pressure
protection
Pressure sensor Cooling
OFF:0.12MPa or less (for 5 minutes)
ON : After 7 minutes