EasyManua.ls Logo

Fujitsu ARU7RLF - User Manual

Fujitsu ARU7RLF
319 pages
Print Icon
To Next Page IconTo Next Page
To Next Page IconTo Next Page
Loading...
AIR CONDITIONER
Multi: 2, 3, 4 rooms type
DESIGN & TECHNICAL MANUAL
INDOOR
AUU7RLF
AUU9RLF
AUU12RLF
AUU18RLF
ARU7RLF
ARU9RLF
ARU12RLF
ARU18RLF ARU24RLF
ASU7RLF1
ASU9RLF1
ASU12RLF1
ASU15RLF1
ASU7RLF*
ASU9RLF*
ASU12RLF*
ASU9RLS2*
ASU12RLS2*
ASU15RLS2*
ASU18RLF
ASU24RLF
AGU9RLF
AGU12RLF
AGU15RLF
*: AOU36RLXFZ1 is not connectable.
OUTDOOR
AOU18RLXFZ
AOU24RLXFZ
AOU36RLXFZ1
DR_MU008EF_07
2018.06.14

Table of Contents

Other manuals for Fujitsu ARU7RLF

Questions and Answers

  • W
    walkerstephanieAug 12, 2025
    What to do if my Fujitsu Air Conditioner remote is not working due to a communication error?
    • C
      Cassandra MyersAug 12, 2025
      If you're experiencing a Wired Remote Controller Communication Error with your Fujitsu Air Conditioner, check the voltage. If it's DC12V, the remote control has failed and should be replaced. If it's DC 0V, the Controller PCB has failed and should be replaced after rechecking the remote control.
  • R
    Roger ConradAug 16, 2025
    What to do if my Fujitsu Air Conditioner has a drainage error?
    • G
      Gary JohnsonAug 16, 2025
      If your Fujitsu Air Conditioner is experiencing drainage issues, start by inspecting the float switch for proper operation using a meter to check its on/off switching. If the float switch is defective, replace it. Also, examine the drain hose for any clogs and clear them if necessary. If these steps don't resolve the issue, consider replacing the controller PCB.
  • B
    Brandon AdamsAug 19, 2025
    How to fix a Fujitsu Air Conditioner indoor unit fan motor error?
    • S
      Stacey GomezAug 19, 2025
      If you're encountering an indoor unit fan motor error with your Fujitsu Air Conditioner, check first the fan and bearing. If either is damaged, replace them. If the motor itself is faulty, replace the indoor unit fan motor. If these steps do not resolve the issue, replace the controller PCB.
  • J
    Jose BooneAug 23, 2025
    What to do if my Fujitsu ARU7RLF shows an indoor room thermistor error?
    • M
      moorechristopherAug 25, 2025
      If your Fujitsu Air Conditioner displays an indoor room thermistor error, begin by checking the connector to ensure it is securely attached and properly connected, and verify that the thermistor cable is not open. If the thermistor is either open or shorted, replace it and then reset the power.
  • M
    Martin WilliamsAug 27, 2025
    How to troubleshoot an Indoor Unit Model Information Error on my Fujitsu Air Conditioner?
    • V
      Virginia HuffAug 27, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Model Information Error, check for external causes such as noise and ensure the ground connection is properly connected. Also, inspect all connectors for looseness or incorrect wiring, and check the PCB for any shorts or corrosion. If the problem persists, consider replacing the Controller PCB.
  • B
    Bianca KimAug 31, 2025
    What does an Indoor Unit Capacity Error mean on my Fujitsu Air Conditioner?
    • T
      tstephensAug 31, 2025
      If your Fujitsu Air Conditioner is showing an Indoor Unit Capacity Error, first verify the total capacity of the connected indoor units. If an abnormal condition is found, correct it by referring to the Installation Manual or Design & Technical Manual. If the problem persists, replace the Main PCB of the Outdoor unit.
  • G
    Gerald StephensSep 3, 2025
    How to fix a Serial Communication Error (Serial Reverse Transfer Error) on a Fujitsu Air Conditioner?
    • J
      Jennifer JenkinsSep 3, 2025
      If your Fujitsu Air Conditioner displays a Serial Communication Error (Serial Reverse Transfer Error), check all connection lines between the indoor and outdoor units for any looseness or disconnections, referring to the Installation Manual or Data & Technical Manual for correction. Also, check the voltage of the power supply, ensuring it appears at the outdoor unit terminal L1 - L2 within the range of AC187V - 253V. Check that the indicated value swings between AC90V and AC270V at outdoor unit terminal 1 - 3. If the outdoor fan motor, active filter module, or IPM is abnormal, replace the corresponding part. If all parts are normal, replace the Main PCB.
  • C
    Carol BestSep 7, 2025
    How to resolve a Damper (Open/Close) simultaneous detection Limit switch error on a Fujitsu ARU7RLF?
    • B
      Brett OlsenSep 7, 2025
      If your Fujitsu Air Conditioner displays a Damper(Open/Close) simultaneous detection Limit switch error, replace the limit switch if it is defective. If the problem persists, replace the Controller PCB.

Summary

Part 1. INDOOR UNIT

2. Specifications

Technical specifications for Fujitsu Compact Cassette, Slim Duct, Wall Mounted, and Floor indoor units.

3. Dimensions

Physical dimensions and installation clearances for various indoor unit types.

8. Noise Level Curve

Noise level curves for Compact Cassette and Slim Duct indoor units across frequency bands.

10. Safety Devices

Details on protective mechanisms and safety features for indoor units.

11. External Input and Output

Information on external control inputs and outputs for indoor units.

Part 2. OUTDOOR UNIT (2 ROOMS TYPE)

1. Specifications

Technical specifications for Fujitsu AOU18RLXFZ outdoor units.

2. Dimensions

Physical dimensions and connection points for the AOU18RLXFZ outdoor unit.

3. Installation Space

Required installation clearances and space for the AOU18RLXFZ outdoor unit.

6. Capacity Table

Capacity tables for cooling based on indoor unit combinations for AOU18RLXFZ.

10. Operation Noise (Sound Pressure)

Sound pressure level curves for the AOU18RLXFZ outdoor unit across frequencies.

12. Safety Devices

Safety features and protection forms for the AOU18RLXFZ outdoor unit.

Part 3. OUTDOOR UNIT (3 ROOMS TYPE)

1. Specifications

Technical specifications for Fujitsu AOU24RLXFZ outdoor units.

2. Dimensions

Physical dimensions and connection points for the AOU24RLXFZ outdoor unit.

3. Installation Space

Required installation clearances and space for the AOU24RLXFZ outdoor unit.

6. Capacity Table

Capacity tables for cooling based on indoor unit combinations for AOU24RLXFZ.

10. Operation Noise (Sound Pressure)

Sound pressure level curves for the AOU24RLXFZ outdoor unit across frequencies.

12. Safety Devices

Safety features and protection forms for the AOU24RLXFZ outdoor unit.

Part 4. OUTDOOR UNIT (4 ROOMS TYPE)

1. Specifications

Technical specifications for Fujitsu AOU36RLXFZ1 outdoor units.

2. Dimensions

Physical dimensions and connection points for the AOU36RLXFZ1 outdoor unit.

3. Installation Space

Required installation clearances and space for the AOU36RLXFZ1 outdoor unit.

6. Capacity Table

Capacity tables for cooling based on indoor unit combinations for AOU36RLXFZ1.

10. Operation Noise (Sound Pressure)

Sound pressure level curves for the AOU36RLXFZ1 outdoor unit across frequencies.

14. Optional Parts

Details on optional accessories such as adapter kits for system combinations.

15. Outdoor Unit Installation Precautions

Important precautions for installing outdoor units to ensure safety and performance.

Fujitsu ARU7RLF Specifications

General IconGeneral
BrandFujitsu
ModelARU7RLF
CategoryAir Conditioner
LanguageEnglish