SPECIFICATIONS
INDOOR UNIT
H x W x D (mm)
H x W x D (mm)
275 x 790 x 215
OUTDOOR UNIT
540 x 790 x 290
DIMENSIONS
INDOOR UNIT
GROSS / NET (kg)
GROSS / NET (kg)
12 / 9
OUTDOOR UNIT
42 / 3839 / 35
WEIGHT
TYPE
COOL & HEAT INVERTER
INDOOR UNIT
AS*12LSBCW
OUTDOOR UNIT
AO*12LFBC
AS*9LSBCW
AO*9LFBC
COOLING CAPACITY
(kW) 3.50
HEATING CAPACITY
(kW)
4.80
POWER SOURCE (V) 230
FREQUENCY (Hz)
50
RUNNING CURRENT
COOLING 4.3
(A)
HEATING
5.6
INPUT WATTS
(kW)
COOLING 0.92
HEATING
1.23
E.E.R.
COOLING
3.80
COP HEATING
3.90
MOISTURE REMOVAL
1.8
AIR CIRCULATION-Hi (m /hr)
3
C 635 H 670C 595 H 645
2.60
3.60
3.0
3.8
0.62
0.82
4.19
4.39
1.3
FAN MOTOR
TYPE
Hermetic type, 4 pole, 3 phase,
DC inverter motor, Rotary
DISCRIMINATION DA 89 X 1F - 20F
REFRIGERANT R410A (g) 1,050950
POWER SOURCE (V) 230
HI-SPEED (r.p.m.) C 1,300 H 1,390
INDOOR
UNIT
MED-SPEED (r.p.m.) C 1,120 H 1,200
LO-SPEED (r.p.m.) C 950 H 1,000
QUIET (r.p.m.) C 700 H 760
C 1,370 H 1,440
C 1,150 H 1,200
C 950 H 1,000
C 700 H 760
OUTDOOR UNIT (r.p.m.) C 830 H 830C 840 H 840
ELECTRICAL DATA
COMPRESSOR
( /hr)
INDOOR UNIT
(dB) C 43 H 43
OUTDOOR UNIT
(dB) C 47 H 49
C 42 H 42
C 47 H 48
NOISE LEVEL
REFRIGERANT (R410A)
Pipe Length
15 m 950 g 1,050 g
FULL CHARGE AMOUNT
20 m 1,050 g 1,150 g
ADDITIONAL REFRIGERANT
20 g / m
(kW/kW)
(kW/kW)
THICKNESSES OF ANNEALED COPPER PIPES
Nominal diameter
1/4
3/8
Outer diameter (mm)
6.35
9.52
R410A
0.80
0.80
[ref,] R22
0.80
0.80
Thickness (mm)
01-02

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Fujitsu AS*12LSBCW and is the answer not in the manual?

Fujitsu AS*12LSBCW Specifications

General IconGeneral
BrandFujitsu
ModelAS*12LSBCW
CategoryAir Conditioner
LanguageEnglish

Related product manuals